29
9.15 Plasma dust collector function(optional)
The indoor unit is equipped with Plasma, which is controlled by the TURBO button on the remote controller when
the unit is turned on. Press the TURBO button at least 2 second to activate the function. Press it again (at least
2 second) to stop the function. During the time when Plasma being controlled by remote controller, Plasma will
be turned off automatically, if indoor fan stops running due to malfunctions or anti-cold-wind. When indoor fan
restarts after malfunctions being eliminated and anti-cold-wind being released, Plasma will be available again.
9.16 Outdoor chassis heating cable
Heating cable is fixed on o
utdoor chassis to help deicing and to avoid freezing. The heating cable’s power is 85W,
rated voltage is 220v-240v, and is controlled by the program. If outdoor temperature is lower than 5
℃
, the heating
cable begins to work. If outdoor temperature is higher than 15
℃
, the heating cable stops working.