OPERATION
MANUAL OPERATION
Operation of the heater is under the direct control of the user. Heat output will, however, be automatically
adjusted in accordance with the room temperature registered by the temperature sensor.
1. Turning Heater ON
A. Press ON/OFF switch to “ON” position. The current room temperature and the set temperature will be
shown on the digital indicator. ON lamp will start to flash and then blower motor and ignition will start. This
lamp will continue to flash during the preheating time.
B. After approx. 1.5 – 4 minutes ignition will take place. (*) After ignition, ON lamp will change flashing to
continuous. Circulation fan will turn on after approx. 2 minutes.
NOTE: (*) Pre -heating depends on the room temperature.
Room temperature:
under 0˚C
4
minutes
0˚C - 15˚C 2
minutes
15˚C
1.5 minutes
2. Adjusting Room Temperature
A. Press the “
▲
MIN.” or “
▼
HOUR” button. ˚F or ˚C will start to flash.
NOTE: The“
▲
MIN.” or “
▼
HOUR” button will change the temperature in increment of 1˚C (2˚F).
B. Press the “
▲
MIN.” or “
▼
HOUR” button as required. Room temperature can be set from 10˚C (50˚F) to 32
°
C
(90˚F). (Initial setting : 13˚C (56˚F))
NOTE: Desired temperature setting will be displayed on the digital indicator when you set the room
temperature.
C. When room temperature reaches the selected setting, heater will automatically shift to “MED” or “LOW”
burning mode to maintain the desired temperature.
When room temperature exceeds the selected setting by approx. 2˚C (4˚F), the heater will automatically shut
off. As room temperature drops, the heater will automatically re-start to maintain the desired temperature.
Approx. +2˚C
Approx. +1˚C
SET
TEMP.
High
Medium
Low
Off
Re-lgnition
9