(i) Add more coolant, and repeat steps (h) and (i).
HINT: By performing steps (h) and (i), 0.2 – 0.5 liters
(0.2 – 0.5 US qts, 0.2 – 0.4 Imp. qts) can normally be
added.
(j) Check that coolant level in the water filler has not
dropped.
If the coolant level has dropped, add coolant and
repeat the steps from (g) onward.
(g) Fasten the radiator (water filler) cap to the 1 st stop
point.
NOTICE: Do not tighten the radiator cap completely (to
the 2nd stop point).
(h) Start the engine, and run at idle for approx. 3 minutes,
and stop the engine.
(f) When the coolant level in the air drain service hoses
stops dropping, close the air drain plugs of the radi–
ator and heater water valve.
(k) Completely tighten the radiator (water filler) cap.
–
3S–GTE ENGINE
COOLING SYSTEM
EG1–422