Removal of EV Battery Assembly
WARNING:
•
Be sure to wear insulated gloves when handling high-voltage parts.
•
Even if the vehicle is shut off and the relays are off, be sure to remove
the service plug grip before performing any further work.
•
Power remains in the high voltage electrical system for 10 minutes even
after the EV battery pack is shut off because the circuit has a condenser
that stores power.
•
Make sure that the tester reading is 0 V before touching any
high-voltage terminals which are not insulated.
•
The SRS may remain powered for up to 90 seconds after the vehicle is
shut off or disabled. To prevent serious injury or death from
unintentional SRS deployment, avoid cutting the SRS components.
1. SHUT OFF IGINITION (
READY
indicator is off)
2. REMOVE 12 V AUXILIARY BATTERY
(1) Open the hood.
(2) Disconnect the cable from the auxiliary battery
negative (-) terminal.
(3) Disconnect the cable from the auxiliary battery
positive (+) terminal.
(4) Remove the 12 Volt auxiliary battery.
3. REMOVE CENTER FLOOR HOLE COVER
(1) Move the front seat assembly LH to the
rearmost position.
(2) Turn back the center floor hole cover carpet.
20