Technical information
Product guide – BT Levio W-series
54
u measurement
The u measurement is the distance between
fork●tip●and●the●wheel-fork●pivot●
point
.
T measurement
The measurement
from●back●of●forks●to●the●wheel●fork●pivot●point
is called the
T measurement. The T measurement can be calculated with the formula:
T =
l
-u
As an example the u and T measurements are important for long side handling of
pallets. With incorrect u and T measurements, the fork wheels will not fit between
the pallet legs. As a result, the truck will crush the pallet during lift operation.
p measurement
The p measurement is also a measurement that can be used to determine placement
of the fork wheels.
The p measurement is described as the
distance●from●fork●tip●to●front●face●of●
fork●wheel,●fork●down
.
Single wheel, 85 mm
Bogie wheel, 85 mm
LWE140/160 Narrow forks
p=u-164
p=u-221
LWE180/200/250 Standard forks
p=u-158
p=u-203
u
u
u
T
Pallet broken due to incorrect
u- and T-measurements
p