INSTALLATION OF HEATER AND FLUE PIPE
IMPORTANT:
Check and comply with all state and local codes that may apply to vented heaters before
beginning installation.
NOTE:
This heater is designed to be used no more than 3000 FT. above sea level.
ASK your local dealer for using at altitudes higher than 3000 FT. above sea level.
1.
Select heater location. Allow clearances as indicated below between heater and all other materials.
(See Fig. 1)
2.
Make sure that the outside area to where the standard flue pipe will reach is clear of any objects.
(See Fig. 2 & 3)
NOTE:
Flue pipe can be installed through any standard building materials. Please ask your local dealer
or distributor for more details.
NOTE:
The wall thickness which the flue pipe can be installed is from 4 in. to 9 in. If it is more than 9
inches, consult your local dealer.
22
More than 2 ft.
More than 4 inches
More than 1 ft.
More than 1 ft.
More than 5 ft.
Fig. 1
Fig. 2
Fig. 3