10. Operation

                                                                       

 

 

     

(1) The data frame to be transmitted to the receiving unit is sent as soon as it is input to this equipment 

from an external device. Data equivalent to 1 frame is not accumulated inside the equipment. 

 

     

(2) Data frame sent from the receiving unit is sent to an external device as soon as it is received. 

 

     

(3) Functions of sending data indicator lamp (SD) and receiving data indicator lamp (RD) 

       

  Sending data indicator lamp (SD) blinks in red when sending input is active. 

       

  Receiving data indicator lamp (RD) blinks in green when receiving input is active. 

 

     

(4)When optical path is shielded, the receive indicator lamp goes off, and no data can be   

sent any longer. Reception level is not displayed, either, at the receiving unit. 

 

     

(5)Functions of link indicator lamp (LINK) and full-duplex indicator lamp (FDX) 

Link indicator lamp (LINK) shows green when the network connection with the external device 
connected to the signal connector is normal.   
Full-duplex indicator lamp (FDX) shows green when the network connection with the external 
device connected to signal connector is in full-duplex mode. 

 

     

(6) Aux. output operates as shown below. 

       

  1) DL: Transistor turns on when the data ling is normal. 

       

  2) ALM: Transistor turns off when the reception level indicator lamp (LEVEL 1) is off. 

 

     

(7) The statuses of indicators and subsidiary outputs change as shown below when the beam is received 

or interrupted. 

Unit 1 

Unit 2 

Condition 

Light intensity 

received by 

this unit 

Light intensity 

received by the 

other unit 

DL 

output 

ALM 

output 

Light intensity 

received by 

this unit 

Normal 

L1 or more 

L1 or more 

ON 

ON 

The same with 
(1) 

Insufficient light 
intensity (cleaning or 
beam adjustment 
required) 

CD only 

CD or more 

ON 

OFF 

The same with 
(1) 

Interrupted (cleaning or 
beam adjustment 
required) 

Off 

Off 

OFF OFF Off 

CD 

or 

more  Off 

OFF OFF CD 

or 

more 

Affected by external 
disturbance or reflected 
light 

L1 

or 

more  Off 

OFF OFF CD 

or 

more 

Note:   If the system is affected by an external disturbance or reflected light, different 

values will be indicated by units 1 and 2 to represent the light intensity received 
by unit 2. 

 
 

Summary of Contents for SOT-ES100 Series

Page 1: ...DS4 2511C 1 Optical Transmitter SOT ES100 Series Operation Manual TOYO ELECTRIC CORP...

Page 2: ...tions of Components 5 6 Installation 6 7 Electric Connections and Wiring 8 8 Setting Switches 10 9 Adjustment of the Optical Axis 11 10 Operation 12 11 Signal Interface 13 12 Maintenance and Inspectio...

Page 3: ...external devices is made by means of a connector maintenance can be performed easily This equipment is specified for use in DC24V power 3 Configuration 1 Model SOT ES 1 0 0 Option Combination of trans...

Page 4: ...amp green Shows green when received data output is on FDX Full duplex indicator lamp red Shows red in full duplex connection Own unit CD Clear data indicator lamp red Shows red at a sufficient recepti...

Page 5: ...Receiving data indicator lamp RD Blinks green when the received data output is ON 8 Link indicator lamp LINK Shows green when 10BASE T link is established 9 Full duplex indicator lamp FDX Shows green...

Page 6: ...e near a magnet motor or other devices that generate a strong magnetic field or an inverter or another devices or electric wire that generate a strong noise 5 A place where the sunlight or candescent...

Page 7: ...nication area after adjustment of the optical axis according to section 9 Adjustment of the Optical Axis Example 1 Type A Type A Type B Type B 1 5 m or more 3 m or more Type A Type A Type A Type A Typ...

Page 8: ...onnected 8 Transmission output and reception input may be exchanged according to the connected cable AutoMDIX function Polarity of reception input may be exchanged according to the connected signal po...

Page 9: ...r or external device 2 For power supply use one conforming to the specification of this machine 3 For the load of aux output connect one within the output rating 30VDC 50mA of this machine When connec...

Page 10: ...OFF ON Set items so that the communication mode of Full duplex Half duplex may conform to the device connected in the receiving side across the optical transmitter Special care must be taken when conn...

Page 11: ...or more First adjust by referring to the display of reception level on the receiving unit 3 Make further fine adjustment until the reception level indicator lamps on the receiving unit show green up t...

Page 12: ...Full duplex indicator lamp FDX shows green when the network connection with the external device connected to signal connector is in full duplex mode 6 Aux output operates as shown below 1 DL Transist...

Page 13: ...within 100 m Note 2 For power wire use electric wire of 0 3 mm2 or more Extension of power wire shall be within 50 m if power voltage is 24VDC Note 3 Voltage between DL COM or ALM COM shall be 30VDC o...

Page 14: ...wer to the equipment Data cannot be transferred for further 2 sec or so because of auto negotiation when such auto negotiation is effective 3 Optical axis adjustments Do not fail to adjust optical axi...

Page 15: ...D LEVEL1 4 Ethernet connector 1 RJ45 Clear data indicator lamp receiving unit 5 CD LEVEL1 4 Mounting seat 1 Communication indicator lamp 4 SD RD LINK FDX Mounting fixture 2 ABS resin black FG terminal...

Page 16: ...DS4 2511C 16...

Page 17: ...e Machinery Division Kamiya Factory TOYO ELECTRIC CORP Electric Machinery Div Head Office Hikisawa 1 39 Kamiya cho Kasugai Aichi Japan 480 0393 Kamiya Plant TEL 0568 88 1181 FAX 0568 88 3086 Tokyo Off...

Page 18: ...2 correction of pin number of aux output Development 2007 04 20 A power supply an assistance output connector model change an error in writing correction an address change Development 2007 11 30 Chan...

Reviews: