MOVEMENT SENSOR 360

°

(CEILING MOUNTING) 

T 76 251 

 

Technical Manual 

 

Toyama Movement sensors are 

intelligent lighting control energy saving sensitivity detectors. Movement 

sensors use Passive infrared (PIR) sensor to detect the human movement and make corresponding triggering of 

loads, say lights. Usage of SMD components not only ensures reliability but also makes the product highly 

compact for its functionality and features. Wide operating voltage range of the Movement sensors makes it 

operational across countries from North America having 127V supply to European countries with 230V supply 

without any field setting. The device is incorporated with the adjustable inbuilt timer to switch OFF the load when 

there is no human movement. The device is also incorporated with Lux detector. 

 Applications:

  Movement sensors can be installed in 

 Office 

/Hotel 

corridors. 

 Stair 

cases/Passage. 

 Stores, 

Classrooms. 

  Common fresh rooms. 

SPECIFICATIONS: 
 

Supply 

voltage 

   : 

 

110 

250V/AC 

  

Supply frequency 

 

 

:  

50-60 Hz 

Rated load 

 

 

 

1200W  resistive 

Detection 

angle 

   : 

 

360 

°

 

Detection distance 

 

 

:  

10 feet radius with normal walking  at < 24 deg. C  

Installation height 

 

 

8-9 feet optimum 

Detection motion speed  

 

0.6 - 1.5m/s 

Delay OFF  time 

 

 

Minimum:  30 sec / Maximum:  450 sec 

Lux adjustment level 

 

 

:  

10 – 400 lux 

Power consumption 

 

 

:  

0.45W (Static 0.1W) 

Operating Temperature   

 

0 - 55

°

C

 

Standard color of Movement sensor 

White 

SENS

PHOTO

TIME

PHOTO

Keep in

TIME

Adjust delay time from 30 sec 

min(-) to 7 minutes max(+)

SENS

Keep at + for maximum 

sensitivity and - for minimum 
sensitivity

for day/night mode

and in

for night mode

 

Summary of Contents for T 76 251

Page 1: ...ilt timer to switch OFF the load when there is no human movement The device is also incorporated with Lux detector Applications Movement sensors can be installed in Office Hotel corridors Stair cases Passage Stores Classrooms Common fresh rooms SPECIFICATIONS Supply voltage 110 250V AC Supply frequency 50 60 Hz Rated load 1200W resistive Detection angle 360 Detection distance 10 feet radius with n...

Page 2: ...epute If required connect 2 2uF 440V AC Fan Capacitor across CFL with electronic ballasts to avoid blinking of lamps when it is OFF Connect upto specified wattage of load only For higher loads suitable rated contactor of reputed make can be used Hindrance moving object should not hide the detection window Avoid installing in Bathrooms Make sure air conditioners central heating etc do not cloud IR ...

Page 3: ...ion distance may vary according to the installation position and detection field Time delay adjustment The timer knob can be set according to the customer needs The minimum is 30 sec and the maximum is 450 sec delay OFF Identifies day and night automatically When the trimmer knob is turned towards SUN Position max it will switch ON lights both in day and night When turned towards MOON position min...

Page 4: ...t the connections Turn the lux level adjuster photo fully clockwise Sensitivity is poor Installation height may be high The sensitivity level adjuster may be low side Incorrect moving orientation Obstruction in front of sensor window Install at recommended height Turn the sensitivity level adjuster to high side Correct moving orientation Remove the obstruction in front of the window DIMENSIONS 33 ...

Reviews: