Maintenance
58
TOX_Manual_FinePress_PFS-PFL-PFW_en
10.3.3
Inspecting and cleaning movable parts and guides
ü
System is in maintenance position.
See
Set system to maintenance position, Page 55
NOTE
Incorrect cleaning agents or cleaning processes, lack of corrosion
protection!
Damage to machine components!
è
Only touch bare areas with gloves.
è
Use cleaning set, such as industrial cleaner (e.g. Loctite 7063, or Würth
Montagekraftreiniger 0890 107), vacuum cleaner, dry cloth and brush.
è
Do not clean with compressed air but with suction.
è
After cleaning, protect bare outer surfaces from corrosion. Coat sur-
faces with a cloth slightly moistened with anticorrosive fluid.
è
Keep inside surfaces, especially element-carrying parts, dry and free of
grease.
è
Inspect movable parts and guides, clean and lubricate if necessary.