Maintenance
TOX_Manual_FinePress_PFS-PFL-PFW_en
55
10.2
Requirements for maintenance
10.2.1
Set system to maintenance position
Unless specified otherwise, before all maintenance work:
1.
Retract the working piston.
w
Drive is in home position.
2.
Install a restraint device if necessary.
3.
Switch off the system and secure it against being switched back on.
4.
Turn off compressed air unless expressly stated otherwise.
5.
Make sure that unauthorized, accidental or unexpected starting up of
the machine and initiation or dangerous movements due to latent ener-
gies are prevented.