Installation
TOX_Manual_FinePress_PFS-PFL-PFW_en
29
6 Installation
6.1
Safety during installation
The installation may only be carried out by trained and authorized service
personnel.
DANGER
Electrical hazards in case of contact with live parts!
Electric shock, burns or death in case of contact with live parts!
è
Have all work on the electrical equipment performed by an electrician.
è
Disconnect power supply.
è
Wait for residual energy to disspate safely (at least 3 minutes).
WARNING
Ejecting parts and compressed air from compressed air conducting
lines!
Serious injuries to eyes and body cavities!
è
Always connect and disconnect lines without pressure.
è
Pay attention to maximum permitted pressures.
è
Wear individual protective equipment.
WARNING
Hazard from suspended loads!
Severe crushing, impacts and serious accidents as a result of improper
transportation and falling load!
è
Only use lifting gear that is appropriate and in perfect technical condi-
tion, as well as load attachment devices with an adequate safe working
load.
è
Never stand or work under suspended loads.
è
Make sure that that no person is in the danger area.
è
When transporting and setting down, make sure that no parts of the
body become jammed.
è
Wear suitable personal protective equipment (e.g. safety boots).
Summary of Contents for TOX-FinePress PFL 002
Page 2: ...2 TOX_Manual_FinePress_PFS PFL PFW_en ...
Page 12: ...Important information 12 TOX_Manual_FinePress_PFS PFL PFW_en ...
Page 22: ...About this product 22 TOX_Manual_FinePress_PFS PFL PFW_en ...
Page 24: ...Technical data 24 TOX_Manual_FinePress_PFS PFL PFW_en ...
Page 52: ...Maintenance table 52 TOX_Manual_FinePress_PFS PFL PFW_en ...
Page 60: ...Repairs 60 TOX_Manual_FinePress_PFS PFL PFW_en ...
Page 64: ...Disassembly and Disposal 64 TOX_Manual_FinePress_PFS PFL PFW_en ...
Page 66: ...Appendices 66 TOX_Manual_FinePress_PFS PFL PFW_en ...
Page 67: ......
Page 68: ......
Page 72: ...Index 72 TOX_Manual_FinePress_PFS PFL PFW_en ...