TownSteel Prodigy SmartLock 4000 Series Programming Manual Download Page 5

YW1838 

 

 

Important Notes

 

 

To wake up the touch keypad from idle mode, gently swipe or tap the keypad.

 

 

While in Factory Default Settings, the lock will flash 

red

 and then 

green

. Any credential will open the lock until a Master 

Code in programmed into the lock.  

 

The Factory Default Setting

’s Master Code must be changed before programming any other codes or system settings. 

 

The Master Code cannot be deleted. 

 

A Master Code or User Codes can be 6-10 digits (they do not need to be the same code length).  

 

Same credential, code or keycard, cannot be programmed twice in a lock.  

 

To open the lock using a valid credential 

– enter a User Code or Master Code followed by Pound (#) or swipe a 

Keycard/Fob. This will be followed by a 

green

 LED and the lock will open for 5 seconds before automatically re-locking. 

 

Pressing the Asterisk (

) key will cancel any on-going code input or programming sequence. Pressing Asterisk (

) two 

times will set the lock on idle. 

 

Pressing the Asterisk (

) key followed by Pound (#) and entering the Master Code opens programming. 

 

During programming, allow 

for the lock’s sounds to end before pressing any keys to make sure the system recognizes 

the programming sequence. 

 

During programming, the 

green

 LED indicates success and the 

red

 LED indicates failure. 

 

Outside of programming, the 

green

 LED indicates unlocked and the 

red

 LED indicates locked.  

 

To prevent unauthorized entry, the lockout feature is activated for 1 minute and 30 seconds after 5 invalid credential 
inputs have been inputted. During lockout, no credential will be accepted. Penalty time is 1 minute and 30 seconds, and 
the 

red

 LED and alarm will operate repeatedly for the duration of the penalty. 

 

This lock features anti-pry cryptographic functions. Users can add random digits before and/or after a valid code. Enter a 
valid code 

in the following method: “XXXCODEXXX” (limited to 15 random digits) followed by Pound (#).      

 

Replacing batteries does not change existing settings.

 

 

The symbols        and          are used in this programming guide to represent the audio and visual cues the lock uses to show 
successful progression during the programming process. 

Disclaimer: The codes used in the following examples are not recommended for actual valid codes - accepted protocol 
should be followed for secure codes - repeated strings of numbers are not secure. 

Summary of Contents for Prodigy SmartLock 4000 Series

Page 1: ......

Page 2: ...tes 4 Change Master Code 5 Add Credentials 5 Add a User Code Add Multiple User Codes Add User Keycards Delete Credentials 7 Delete User Code Delete User Keycard Reset to Factory Default Settings System Settings 8 Dual Verification Sound Reset Lock to Factory Default Settings 9 Low Battery 9 ...

Page 3: ...k has one Master Code Master Code cannot be deleted User Code User Codes are used to operate the lock User Codes are programmed by the Master Code The lock can have a maximum of 397 User Codes interchangeable with Keycards Fobs User Keycard Fob Keycards or Fobs can be used to operate the lock Master Code is used to program User Keycards Fobs Swipe the touch keypad with a Keycard Fob to operate the...

Page 4: ...n locked position meaning deadbolt is extended 2 Confirm handing indicator on battery tray is in correct position RH Right Hand or LH Left Hand 3 Confirm lock spindle is in correct position Horizonal Position for RH or Vertical Position for LH 4 Wake up keypad by swiping or tapping surface and press 0 key followed by key After pressing 0 then deadbolt will retract then extend again This means lock...

Page 5: ...g allow for the lock s sounds to end before pressing any keys to make sure the system recognizes the programming sequence During programming the green LED indicates success and the red LED indicates failure Outside of programming the green LED indicates unlocked and the red LED indicates locked To prevent unauthorized entry the lockout feature is activated for 1 minute and 30 seconds after 5 inval...

Page 6: ... liability direct or indirect due to failure to change Master Code No other programming will be accepted until Factory Default Setting s Master Code has been changed Master Code can be changed at any time Changing the Master Code does not affect other lock settings A lock has only one Master Code Multiple locks can have the same Master Code Add Credentials Add a User Code Key Sequence For example ...

Page 7: ...nd 404040 press Notes The input of additional credentials must start before lock goes into Idle Mode 12 seconds If the lock goes into Idle Mode start the key sequence from the beginning To exit press asterisk or wait until the lock goes into Idle Mode 12 seconds Add Keycard or Key Fob Key Sequence For example the Master Code in sequence above is 555555 ...

Page 8: ... wait until the lock goes into Idle Mode 12 seconds Delete Credentials Delete User Codes Key Sequence For example to delete User Code 222222 assuming the Master Code is 555555 press Delete User Key Cards Key Sequence Notes Multiple Keycards Fobs can be deleted during the same programming sequence like Additional User Codes Key Sequence To exit press asterisk or wait until the lock goes into Idle M...

Page 9: ...uence Notes Dual Verification Mode when enabled requires 2 valid credentials to operate the lock A credential can be a Master Code User Codes or Keycards Fobs The Factory Default Setting is set to one credential Adjust Keypad Sound Key Sequence Notes Disabling the sound only affects general operation not during programming of the lock During programming mode lock will temporarily re enable sound ...

Page 10: ...et Result Lock is reset to Factory Default Settings All codes are deleted and Master Code changes to 123456 Low Battery Warning When the battery voltage is low unlocking the lock will activate a sound indicator as well as a yellow LED followed by a red LED to indicate low power Batteries should be changed as soon as this happens When locking under low battery voltage condition the lock will only u...

Page 11: ...10 ...