background image

LANGDALE SMOKE CONTROL    ISSUE 1    07/07/2015 
 

 

The Town and Country Fires Guarantee 

 
 

Town and Country Fires Ltd guarantee the quality of workmanship of their multi fuel stoves for twelve 
months from the date of purchase. 
 
Stoves must be installed to current Building Regulations National and European Standards and per our 
Installation / User instructions supplied with the stove. Installation must be carried out by a competent 
installer. 
 
Using a non approved fuel may cause damage to the stove and will not be covered by our guarantee. 
Wood needs to be dry and seasoned (maximum 20% moisture content). Do not use household coal, 
petroleum based fuels, Petrocoke,Cozycoke,Excell, Burnwell and Anthracite. (A comprehensive list of 
approved fuels for closed appliances is available on the HETAS website)   
 
Usage of our multi fuel stoves should be as per our Installation / User Instructions provided with the stove. 
 
Any warranty claim requires Proof of defective workmanship and delivery of the defective product to our 
factory within twelve months of the date of purchase. 
 
Parts which are classed as consumables and are excluded from our Guarantee include; 
 
Grates, Fire Bricks, Baffles, Fuel Guards, Ash Pan, Glass, Door / Glass Seals and Paint. 
 
Claims under this guarantee should be made through the Approved Town and Country Dealer the 
appliance was originally purchased from. 
 
Please complete the enclosed form in full to validate your guarantee, and extend the guarantee from one 
year to ten years. Please note the extended guarantee is only valid when your stove was purchased from a 
Local Approved Town and Country Dealer and not a third party reseller. 
 
Town and Country Fires are not liable for any incidental loss, damage or injury, however caused. 
   
This Guarantee is only applicable in the UK . 
 
This Guarantee does not affect your statutory rights. 
 

Please keep this page for your future reference. 

 
 
 

 
 
 
 
 
 
 

 

Summary of Contents for LANGDALE SMOKE CONTROL

Page 1: ...ide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system WARNING T...

Page 2: ... from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorize smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with the Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern ...

Page 3: ...ke Control a minimum of 200mm at the back and 400mm at the sides must be maintained from combustible surfaces It is a requirement that this appliance is installed on a solid level non combustible hearth conforming to current Building Regulations This appliance has been tested for hearth temperatures and the maximum temperature was 81 degrees C so is also suitable for a 12mm hearth INSTALLATION A m...

Page 4: ...s required preferably made of metal Acollar is welded to the underside of the register plate so that the flue pipe can be placed into the spigot on top of the stove and round the outside of the collar on the register plate so forming a funnel effect In this way any moisture running down the chimney will be directed back into the stove instead of seeping out onto the top of the stove Connect the st...

Page 5: ...touch or wipe the paint during this period as it will be soft and may mark The room should be well ventilated children and pets should be kept away Do not use water to clean the stove either before or after it is cured TURBO BURNER There is a Turbo Burner which brings air in allowing plenty of oxygen into the rear and top of the stove thus burning off gases which normally do not ignite This gives ...

Page 6: ...d The door should be kept closed at all times except when refueling or removing ashes The appliance is designed to operate efficiently with the fire door closed door The door should be kept closed at all times except when refueling or removing ashes Operation with the stove door open can cause excessive smoke The appliance must not be operated with the stove door left open TO RE FUEL THE STOVE Do ...

Page 7: ...VED FUEL MAY CAUSE DAMAGE TO THE STOVE AND WILL NOT BE COVERED BY OUR GUARANTEE WOOD NEEDS TO BE DRY AND SEASONED MAXIMUM 20 MOISTURE CONTENT DO NOT BURN ANY LIQUID FUEL DO NOT BURN WOOD PELLETS DO NOT BURN WOOD CHIPS DO NOT BURN ANY RUBBISH ON THE STOVE DO NOT USE HOUSEHOLD COAL HIGH PETROLEUM BASED FUELS PETROCOKE COSY COKE EXCEL PUREHEAT NEWHEAT BURNWELL OR ANTHRACITE A COMPREHENSIVE LIST OF AP...

Page 8: ...y used in the factory can be obtained from you supplier Warning do not use an aerosol spray near the stove when the stove is alight This appliance should be regularly maintained by a competent service engineer There must be no unauthorised modification of the appliance Any replacement parts must be recommended by the Manufacturer and can be purchased from the approved dealer the stove was original...

Page 9: ...himney Check that the fuel being used is as described and that the operation of this manual is being followed If smoke is being emitted whilst refueling onto a low firebed then kindling should be used IN CASE OF A CHIMNEY FIRE CLOSE ALLAIR VENTS IF POSSIBLE MAKE SURE THERE IS NOTHING COMBUSTIBLE NEAR THE STOVE MOVE PEOPLE AWAY FROM THE ROOM CLOSE THE ROOM DOOR PHONE THE FIRE BRIGADE WARNING NOTE P...

Page 10: ...n completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance and operating tools and warn them to use only the recommended fuel for the stoves Advise the user what to do should smoke of fumes be emitted from the stove The customer should be warned to use a firegua...

Page 11: ...r our Installation User Instructions provided with the stove Any warranty claim requires Proof of defective workmanship and delivery of the defective product to our factory within twelve months of the date of purchase Parts which are classed as consumables and are excluded from our Guarantee include Grates Fire Bricks Baffles Fuel Guards Ash Pan Glass Door Glass Seals and Paint Claims under this g...