The gas control system is located on the right hand side of the fi rebox behind an access
panel and the decorative fi rebox panel (if installed). The fi replace is operated via a wall switch.
The wall control is connected to the fi replace by a 14-2 AWG wire, not supplied with the
fi replace.
Installation
1. Place the fi replace in the desired location.
2. Remove the window from the fi replace.
3. Remove access panel from right hand side of the fi rebox (Fig #23)
4. Remove the cover from the electrical box Fig. #24
5.
Run two 110 V. AC switched electrical supplies to the control box and connect to the
terminal block installed inside the control box(Fig #25). The fi replace operates on 24V
AC supplied by a transformer rated at 110 volts, 60Hz. See wiring diagram on page #31
for correct connections on terminal block.
6. Connect the gas supply to the valve (Fig #26)
ELECTRICAL BOX
COVER
GAS INLET
Fig. #26
Fig. #25
Fig. #24
TERMINAL BLOCK,
ELECTRICAL CONNECTIONS
ACCESS PANEL
Fig. #23
Honeywell Control Valve
Plumbing and Electrical
16
TCWS.54CODE 102813-40