39 9/16"
60 13/16"
29 15/16"
21 3/4"
29 3/4"
5 7/8"
15 7/8"
22 5/8"
45 1/16"
28 5/8"
22 5/8"
39 9/16"
60 13/16"
11 1/2"
21 5/8"
24"
4“
*
CEILING
ADJACENT WALL
OR MANTEL SUPPORT
6”
COMBUSTIBLE FL
OOR
**
* MANTEL CLEARANCE
A
9”
B
6”
C
3”
** MANTEL DEPTH
D
12”
E
6 3/4”
F
1 1/2”
MANTEL CLEARANCE
CHART
UNIT MAY BE RECESSED UP TO 6” WITH
NONCOMBUSTIBLE MASONRY TYPE MATERIAL
Minimum Clearances:
Side standoffs .......................................................0 in.
(0 mm)
Back standoffs ......................................................0 in.
(0 mm)
Top standoffs ........................................................0 in.
(0 mm)
Bottom of appliance ..............................................0 in.
(0 mm)
Adjacent side wall .................................................4 in.
(102 mm)
Ceiling to appliance ............................................24 in.
(610 mm)
*Mantel to appliance .................. ..........See Figure #2
**Maximum Mantel extension .. ..........See Figure #2
Mantel support ......................................................4 in.
(102 mm)
Vent pipe including Elbows ............................1 3/4" in.
(45 mm)
Fig. #1
Fig. #2
MAY USE COMBUSTIBLE
FACING MATERIAL IN THIS AREA
NON-COMBUSTIBLE
FINISH MATERIAL
SEE FIG #8 & 9
NON-COMBUSTIBLE ZONE.
DO NOT INSTALL ANY COMBUSTIBLE MATE-
RIAL, ELECTRICAL WIRING OR GAS PLUMBING
IN THIS AREA.
COMBUSTIBLE FRAMING AND
FINISH WALL ABOVE STANDOFFS
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF LINTEL BAR
A
B
C
D
E
F
Fig. #3
5
TCWS.38CE3 250313-44
Fireplace Dimensions
Minimum Clearances to Combustible Material