Access panel
Figure 4: Access panel.
310317-20 TCVT.PVCV
5056.42665-A
The gas control system is located on the right hand side of the firebox behind an access panel and the deco-
rative panel.
1. Remove burner assembly, burner media and decorative panels if already installed (see main installation
manual for details).
2. Remove access panel from right hand side of the firebox (Figure 4).
3. Locate and disconnect the spade connectors in the black wire loop on the right side of the module and in
the orange wire running from the module to the socket labelled “pilot”on the valve (Figure 5 and Figure 6).
4. Using the jumper wires provided, connect the 120V “hot” supply wire to one of the black wires from the
control module. Then connect the “hot” wire from the power vent blower to the other black wire on the
control module (Figure 7). The module acts as a switch to turn on the power vent blower. (Also see wiring
diagram on Pg.14)
Spade connector in black wire loop
Figure 5: Locating black wire spade connector.
6
Control System Connection
For “Series C” Fireplaces