310317-20 TCVT.PVCV
5056.42665-A
11
Control System Connection for “Series D” Fireplaces
The gas control system is located on the right hand side of the firebox behind an access panel and the deco-
rative firebox panel (if installed). The fireplace is operated via a wall control and a hand held remote control
unit.
The wall control is connected to the fireplace by a 40 ft. communication cable supplied with the fireplace.
Installation
1. Place the fireplace in the desired location.
2. Remove the window from the fireplace.
3. Remove access panel from right hand side of the firebox (Figure 17).
4. Connect 110 V. AC electrical supply to the wires installed inside the junction box (Figure 18). The fireplace
is rated at 110 volts, 60Hz, 0.25A. The optional power vent kit is rated at 115 volts, 60Hz, 1.8A.
The electrical wires can be accessed from both inside and outside the junction box by removing one of the
two small access panels (Figure 18 and Figure 19).
Firebox access panel
Figure 17: Firebox access panel.
Vent Blower wire - Blue
Power In wire - Black
2 Nuetral wire - Wires
Figure 18: Wiring to power vent at fireplace junction box.