5056.42562
TO HOME
AUTOMATION
SYSTEM
NOTE:
•
Digital I/O must be connected to a dry contact relay.
•
Analog flame and light input through 0 - 10 volt DC
signal scaled as follows:
Low = 1 volt
High = 10 volts
NOTE:
When a signal has been supplied by the home automation system, the fireplace
control will repeat the signal every 2 hours or until a new command has been
received.
Fig. #28
Fig. #29
The home automation feature supplied with this fireplace is capable
of controlling the flame and light on/off function with the use of a dry
contact relay common to home automation systems. Furthermore, the
flame and light level may be modulated from high to low using the
0 - 10 volt analog output available on most home automation systems.
Fig #29 shows the wire designations required to connect the fireplace
to a home automation system.
Home Automation
16
TC54_D 030615-40