NOTE:
•
Digital I/O must be connected to a dry contact relay.
•
Analog flame and light input through 0 - 10 volt DC signal scaled
as follows:
Low = 1 volt
High = 10 volts
Figure 28: Complete communication
wiring.
Figure 29: Home automation wiring diagram.
16
TC42D 301015-48
5056.426D
The home automation feature supplied with this fireplace is capable
of controlling the flame and light on/off function with the use of a dry
contact relay common to home automation systems. Furthermore, the
flame and light level may be modulated from high to low using the
0 - 10 volt analog output available on most home automation systems.
(Figure 29) shows the wire designations required to connect the fire-
place to a home automation system.
Home Automation
Note: Leave the wall switch on the “Remote” setting when using
home automation.
NOTE:
When a signal has been supplied by the home automation system, the fireplace control
will repeat the signal every 2 hours or until a new command has been received.