SUNSTONE POWER CIRQUE EMCHDZ42 Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read all instructions before you operate your grill. 

Save these instructions!

 

Conforms to 
ANSI STD Z21.58-2018 
Certified to CSA STD 1.6-2018 
Outdoor Cooking Gas Appliances 

To installer or person assembling grill:

  

Leave this manual with grill for future reference. 

To consumer:

 Keep this manual for future reference. 

www.sunstonemetalproducts.com 

 

3174816

 

SUNSTONE® POWER CIRQUE™ 

Summary of Contents for POWER CIRQUE EMCHDZ42

Page 1: ...to ANSI STD Z21 58 2018 Certified to CSA STD 1 6 2018 Outdoor Cooking Gas Appliances To installer or person assembling grill Leave this manual with grill for future reference To consumer Keep this man...

Page 2: ...you have the following information MODEL NUMBER DATE OF PURCHASE INVOICE NUMBER For warranty service contact SUNSTONE Customer Service Department at 888 934 9449 Option 1 or email service sunstonemet...

Page 3: ...ation which if not avoided will result in death or serious injury VOLTAGE Indicates a potentially hazardous situation which if not avoided may result in minor or moderate electrical shock EXPLOSION In...

Page 4: ...e maintained All packaging has been removed from Interior of Grill All parts and components are properly installed An installer supplied manual gas shut off valve is fully accessible LP hose is clean...

Page 5: ...SPECIFICATIONS 18 Gauge 304 Stainless steel for 19 Burner 16 Gauge 304 Stainless steel for Griddle 20 Gauge 304 Stainless steel for Hood 18 Gauge 304 Stainless steel body and control panel 20 gauge 30...

Page 6: ...BURNER PARTS LIST PARTS DIAGRAM PAGE 2...

Page 7: ...nsions See next page for Dimension Table Measurements were obtained from engineer drawing margin of error is within 1 8 to actual product Product Size Firebox Size Product Details The Power Cirque Bur...

Page 8: ...l Panel Height 10 1 2 Firebox Size Box Width 22 1 4 Box Depth 22 1 4 Box Height 9 Supporting Lip Overhang 1 Cut Out Details It is always best to first have the Burner On Site if you cannot make sure t...

Page 9: ...clip plug 2 Mount Transformer Using metal screws and attach the transformer to the back inner wall of your island s cabinet wall somewhere near the already installed GFCI electrical outlet When you pl...

Page 10: ...ted at the Right Left and Back sides The grill lip allows it to hang by the three supported edges on the right left and back The front control panel requires no supporting edge it is designed to hang...

Page 11: ...ATTENTION All Gas Grill Installations MUST HAVE MINIMUM TWO AIR FLOW VENTS either in ELEVATED POSITION for Natural Gas or LOWERED POSITION for Liquid Propane Your Warranty may be VOID if island does n...

Page 12: ...inimum Recessed Box Width 28 Min to 30 G Must have TWO Vents in HIGH position for Natural Gas H Must have TWO Vents in LOW position for Liquid Propane I Pot Filler Notch out see page 4 for more detail...

Page 13: ...ible Materials or other Appliance ONLY Non Combustible materials do not apply A From Floor to Overhead Combustible Structure 8 Min Clearance B From Counter to Overhead Combustible Structure 5 Min Clea...

Page 14: ...ed Installation Definition Structure built above Appliance that is attached to the home s exterior outside wall roof or is inside a separate structure like outdoor room and there is a Minimum of One S...

Page 15: ...op level You should take in account that there is a large volume of heat and smoke will exhaust from the rear of the grill This may discolor or damage unprotected areas do not install under unprotecte...

Page 16: ...sure BBQ Grill control knobs are in OFF position Verify the type of gas supply to be used either Natural Gas or Liquid Propane and make sure the marking on the appliance rating label agrees with that...

Page 17: ...h an independent LP regulator for this type of installation Contact the company you purchased from or your local plumber to locate one that is made for commercial style grills Large Capacity LP Tanks...

Page 18: ...the event of a fire The system has a flow limiting device which when activated will limit the flow of gas to 10 cubic feet per hour NEVER use grill without leak testing GAS SETUP MEDIUM CAPACITY LP TA...

Page 19: ...PAGE 15 Follow Instructions 1 The tank valve all Knobs should be in the OFF position If not turn the knob clockwise until it stops 2 Insert the regulator inlet into the tank valve and turn the couplin...

Page 20: ...again Repeat the procedure or try the manual lighting procedure detailed below 7 Upon successful lighting ignite neighboring burners on it is normal to hear a popping sound when the burners are turned...

Page 21: ...sponsible for damage resulting from misuse abuse alteration of or tampering with the appliance accident hostile environment flare up fires improper installation or installation not in accordance with...