TC36_NG03D 091014-20
12
WARNING
This conversion kit
shall be installed by a
qualified service agency
in accordance with the
manufacturer's instructions
and all applicable codes and
requirements of the authority
having jurisdiction.
If the information in these
instructions is not followed
exactly, a fire, explosion
or production of carbon
monoxide may result
causing property damage,
personal injury or loss of
life.
The qualified service agency
is responsible for the proper
installation of this kit. The
installation is not proper and
complete until the operation
of the converted appliance is
checked as specified in the
manufacturer's instructions
supplied with the kit
.
If the unit is to be used on propane
convert as follows using the
components supplied with this
fireplace:
CAUTION
The gas supply and electrical power
shall be shut off before proceeding
with the conversion.
Propane Conversion
CONVERSION LABEL (5052.5208D)
Note: Factory supplied components must be
used to ensure correct input.
After conversion confirm proper manifold
pressure.
1. Ensure the burner, pilot and gas supply
are turned off, and the appliance has
cooled.
2. With a ½” wrench remove the natural gas
orifice and replace with propane orifice
(our part # 5022.92)
(Fig. #19)
3. Fully open the primary air shutter.
4. Remove the pilot shield from the burner
tray by removing two screws (Fig. #20)
5. With a 7/16” wrench loosen the pilot head
on the pilot assembly by a half-turn
(Fig. #21)
Fig. # 20
Fig. # 21
Fig. # 19
MAIN BURNER (2.18 mm)
ORIFICE (5022.92)