background image

080205-8 

TC36.NG01      3

ATTACH PILOT BRACKET TO 

BURNER ASSEMBLY

Fig. # 5

BURNER/GRATE INSTALLATION

1)  Attach the burner assembly to the fl oor shield in the bottom 

of the fi rebox with two screws ensuring that the front edge 
of the burner is fl ush with the front of the shield.

 

See fi g. # 4.

2)  Attach pilot bracket to burner assembly. (Fig. # 5)

3)  Connect fl ex gas line to the manifold assembly and ensure 

the connection is gas tight.

4)  Position the grate in the slots of the burner tray and attach 

to the fl oor shield with two screws through holes located 
behind the front legs of the grate. (Fig. # 6)

Fig. # 4

Fig. # 6

BURNER TRAY INSTALLATION

GRATE INSTALLATION

Summary of Contents for TC36.NG01

Page 1: ...5096 981 B HARDWARE PACKAGE PART TC36 NGHDWR These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE INSTRUCTIONS ...

Page 2: ...e unit The manifold will also need to be repositioned once the burner is installed This is done by removing two retaining screws turning the manifold over and re attaching See Fig 3 DEFAULT INSTALLATION 1 Insert the inlet box into the opening at the base of the right hand side of the unit as shown in fig 1 taking care not to damage pilot plumbing or wires 2 Install 4 screws from the inside of the ...

Page 3: ...he burner is flush with the front of the shield See fig 4 2 Attach pilot bracket to burner assembly Fig 5 3 Connect flex gas line to the manifold assembly and ensure the connection is gas tight 4 Position the grate in the slots of the burner tray and attach to the floor shield with two screws through holes located behind the front legs of the grate Fig 6 Fig 4 Fig 6 BURNER TRAY INSTALLATION GRATE ...

Page 4: ...desired flame affect Reduce the amount used on Propane models as too much will create soot LOG SET ASSEMBLY The logs are packaged in a foam pack inside the box and are fragile and should be handled with care Unpack and inspect log set There should be a total of 6 logs Gas plumbing and vent connections should be completed before proceeding Position the logs as indicated by the following pictures Pl...

Page 5: ...4 Middle Log Placement Step 5 Bottom Left Log Placement 3 4 5 Fig 9 2 5 3 6 1 4 Fig 11 Fig 10 Note Improper placement of logs may cause sooting on internal parts and glass The logs may need to be reposi tioned slightly to avoid excessive flame impingement ...

Page 6: ...kandstringy The shutter may also be opened to enhance the Ember Material glow and lessen the flame height Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before pro ceeding To Adjust See Fig 12 1 Open and remove window frame and set aside See WindowFrameRemoval sectionfoundintheInstallation and Operating Instructions manual 2 Remove the log set and set aside 3 Loos...

Page 7: ...NER TRAY SUPPORT SHIELD 9789 01 7 BURNER TRAY SHIELD GASKET 9789 5 1 2 6 7 5 3 4 REPLACEMENT PARTS DESCRIPTION PART NO LOG SET COMPLETE 5098 7461 REAR 1 shown in fig 11 5098 741 LEFT 2 shown in fig 11 5098 742 RIGHT 3 shown in fig 11 5098 743 MIDDLE 4 shown in fig 11 5098 744 BOTTOM LEFT 5 shown in fig 11 5098 745 BOTTOM CENTRE 6 shown in fig 11 5098 746 Fig 14 IDENTIFICATION NUMBER ...

Page 8: ...2975 Allenby Rd Duncan BC V9L 6V8 Phone 1 888 223 0088 Web site www townandcountryfireplaces net Printed in Canada ...

Reviews: