background image

RESIDENTIAL BURNERS

AFG

 

Oil Burner 240V

240V

Advanced Components

• 

  240V GeniSys Burner Control

• 

 CleanCut Pump

• 

  240V PowerLight Beckett Igniter

• 

 PSC Motor

• 

  Beckett Sound Cover (optional)

Description

The 240 volt AFG burner has technically advanced components to meet increased demand for improved burner 
performance

 for residential, pressure washers and light commercial applications.

 

 These advanced components are 

available on our B2000 series chassis.

 

The 240 volt  AFG’s  performance-enhancing  features

 

will help you meet 

today’s toughest heating system and pressure washer challenges.

Product Sheet 

Outputs:

 

Motor: 208/240 Vac, 5 full load amps (FLA), 30 locked rotor amps (LRA)

 

Igniter: 208-240 Vac, 3 A @ 0.7 PF min

 

Solenoid Valve: 208-240 Vac, 1 A @ 0.7 PF min

 

Thermostat Anticipator Current: 0.1 A  (if applicable)

 

Thermostat Voltage: 24 Vac (if applicable)

Electrical Ratings

Inputs:

 

Voltage: 220-240 Vac (177 to 264 Vac)

 

Current: 100 mA nominal (150 mA max at 264 Vac)

 

Frequency: 50/60 Hz

Beckett GeniSys

Control Part No.

Lockout

Time

Valve-on

delay time

1

Motor-off

delay time

1

Replaces Honeywell:

7560A 0000

15 sec

-

-

R8184G

7560B 1500

15 sec

15 sec

-

-

7560P 1515

15 sec

15 sec

15 sec

-

7560P 1530

15 sec

15 sec

30 sec

-

7560P 152M

15 sec

15 sec

2 min

-

1 - Valve-on delay and motor-off delay timings on all models are programmable with Beckett snap-on 

programming display.  Other factory set timings are available.  Contact Beckett for alternate timings.

GeniSys Controls: 

Models and Settings

Flame Retention Heads

The maximum fi ring rates shown 
are for 60HZ operation.  For 50HZ 
operation the maximum fi ring rate for 
each head is reduced by about 20%.

Reviews: