OPERATING INSTRUCTIONS

The wall mounted rheostat is used to turn the 
blower ON and OFF, as well as to control its 
speed. Please note that the blower will operate 
independently to the fi replace. With the blower 
on heat will be distributed when the fi replace 
is on and room air will be circulated when the 
fi replace is off.

To turn the blower on, rotate the control knob 
clockwise until the switch clicks on. Continue 
to rotate the knob clockwise to reduce the 
blower speed. To turn the blower OFF, rotate 
the control knob counter-clockwise until the 
switch clicks off.

Fig. #11

MAINTENANCE

Town & Country recommends that this kit 
is cleaned at least once a year. It may be 
necessary to increase the frequency of cleaning 
depending on the room location, type of fl oor 
coverings, amount of renovation work, etc.

To clean, remove the grill then use a vacuum 
to clean around the blower and grill, ensuring 
not to damage the fan blades.

CONTROL

KNOB

Summary of Contents for T120.RHKIT

Page 1: ... RHKIT 5055 T120 T120 RHKIT INSTALLATION AND OPERATING INSTRUCTIONS OPTIONAL REMOTE HEAT KIT IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER FOR WOOD FIREPLACES HEAT OUTLET DUCT REMOTE BLOWER ASSEMBLY ...

Page 2: ...ER CASING FACE PLATE 9144 6 BLOWER FAN BRACKET 9146 7 BLOWER WALL BRACKET 9147 8 REMOTE BLOWER BOX TC36 9141 9 BLOWER 5024 65 1 2 3 4 5 6 7 8 9 11 12 13 7 10 WIRE PIG TAIL TC36 50625 11 INLET GRILL 5096 851 12 JUNCTION BOX 5024 408 13 RHEOSTAT KIT 5025 001 REMOTE BLOWER ASSEMBLY Items 5 to 10 TC36 9141 10 ITEM DESCRIPTION PART NUMBER ITEM DESCRIPTION PART NUMBER ...

Page 3: ... kit is affected by the length and number of bends To maximize the performance the length and number of bends should be kept to a minimum ROUND DUCT 6 TYPE B MAXIMUM DUCT LENGTH OF 20 FT RECTANGULAR DUCT 10 X 3 1 4 MAXIMUM DUCT LENGTH OF 20 FT CHIMNEY INSTALLTIONS NOT SHOWN ...

Page 4: ...emote Heat Kit you are installing REMOVE THESE KNOCKOUT PANELS AS NEEDED 2 Remove the insulation directly below the opening down to the heat shield 4 Attach the Duct Adapter Plate to top of unit using 4 screws 3 Install the Flapper Box to the top of the unit Ensure that the flap in the assembly is free to move Flap should be in the normally closed position with the blower off INSULATION REMOVED Fi...

Page 5: ...o the Remote Blower Assembly and seal with aluminium duct tape Run a 6 diameter approved Type B venting between the blower and the fireplace Fasten in place with screws and seal with aluminium foil tape 7 Locate the make up air inlet in a desired location in the chase wall 8 Attach finishing grills over both inlet and outlet using the screws provided Fig 5 BLOWER ASSEMBLY HEAT DUCT TRANSITION BOOT...

Page 6: ... the National Electrical Code ANSI NFPA 70 Latest Edition SPEED CONTROL BLOWER 120 VOLTS 60 Hz 0 7 AMPERES G green L1 white L2 black Fig 10 The Optional Remote Heat blower electrical rating 120V 60HZ 80 watts For your protec tion against shock hazard use only a properly grounded power supply This kit includes a junction box rheostat and cover plate The junction box should be mounted in a convenien...

Page 7: ...e control knob clockwise until the switch clicks on Continue to rotate the knob clockwise to reduce the blower speed To turn the blower OFF rotate the control knob counter clockwise until the switch clicks off Fig 11 MAINTENANCE Town Country recommends that this kit is cleaned at least once a year It may be necessary to increase the frequency of cleaning depending on the room location type of floo...

Page 8: ...8 T120 RHKIT 120913 28 TECHNICAL SUPPORT 1 250 748 1184 Web site www townandcountryfireplaces net 2974 Allenby Road Duncan BC Canada V9L 6V8 ...

Reviews: