background image

MANUAL

OCTOBER 2022 A1

Towelrads.com Ltd,  Queensgate House, Cookham Road, Bracknell, Berkshire RG12 1RB

Telephone: 01628 625 367 | Fax: 01628 659 520 | www.Towelrads.com

SMART THERMOSTATIC

ELECTRONIC CONTROL FOR TOWEL RADIATORS

 

SMART Thermostatic 

is an electronic thermostat for the automatic control 

of electric towel radiators. Using internal sensor, it is capable of keeping the
temperature of the towel radiator to a desired value. Ten different electric 
resistances are available in a range between 100W and 1000W.

Operative modes:

 Comfort, Stand-by/Antifreeze, Boost 2h, P1, P2.

•  Comfort mode:

 The thermostat keeps the towel radiators temperature 

at the level set by the user.

 

•  Boost 2h mode: 

the heating element is activated for a period of 2 

hours independently of the configured temperature. The temperature is 
automatically control LED so as not to exceed 65°C. At the end of the 2 
hour period, the device returns to “

Comfort

” mode.

 

•  P1 and P2 mode: 

The control system enters “Boost” mode for 2 

hours; after that it returns into “

Comfort

” mode for 22 or 10 hours 

(configurable by the user P1 or P2) and then it enters again into “

Boost

” 

mode for 2 hours, repeating the same procedure endlessly. 

•  Standby/Antifreeze mode:

 if the temperature drops below 10°C the 

device will automatically active the control system in order the internal 
liquid freezing

Available colours:

White

Chrome

Black

Anthracite

SMART Thermostatic

 is compliant with the following standards:

•  Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W).
•  EN 60335-1:2012+A11:2014 -EN 60335-2-30:2009+A11:2012
•  EN 60335-2-43:2003+A1:2006+A2:2008
•  EN 61000-3-2:2014 -EN61000-3-3:2013 -EN 62233:2008
•  EN 55014-1:2006+A1:2009+A2:2011 -EN 55014-2:1997+A1:2001+A2:2008

SMART Thermostatic is a certified product:

Summary of Contents for SMART Thermostatic

Page 1: ...mperature The temperature is automatically control LED so as not to exceed 65 C At the end of the 2 hour period the device returns to Comfort mode P1 and P2 mode The control system enters Boost mode f...

Page 2: ...61000 3 3 2013 EN 62233 2008 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 Approval mark CE Case ABS VO Environmental directive WEEE RoHS Operative modes Comfort Boost 2h P1 P2 Stand...

Page 3: ...using carefully ensure that the line voltage is the same as that specified for the thermostat see technical specifications Only use heating elements compatible with the type of used towel radiator Dis...

Page 4: ...ted on the highest side WARNING DO NOT LEAN THE RADIATOR ON THE ELECTRONIC CONTROL 5 Fill the radiator with the specific liquid 6 Put the radiator back in vertical position and check the internal leve...

Page 5: ...ure and further accessory information Boost Programme button For choosing between on of Boost 2h P1 and P2 modes P1 P2 2h Internal NTC sensor Used for automatic temperature control 3 red LEDs indicate...

Page 6: ...s 40 C 45 C 50 C 55 C 60 C 65 C The rightmost lit or blinking LED in the Comfort bar indicates the selected temperature A blinking LED indicates that the corresponding temperature has not yet been rea...

Page 7: ...f 21 hours P2 mode to activate this mode press the Boost Programme button until the LED P2 is lit In this mode the thermostat activates for 2 hours the Boost function after 2 hours the thermostat retu...

Page 8: ...for the whole time that the function is active LED P1 mode LED Boost 2h mode LED P2 mode FUNCTION DIAGRAMS FUNCTION DIAGRAM OR BOOST TIMER LEDS P2 Comfort Boost 2h P1 Press the Boost Programme button...

Page 9: ...Boost 2h P2 and P1 modes The status of the thermostat is saved after 5 seconds from the last modification Accessory To allow a mixed usage of the SMART device connect the T piece to the towel radiato...