tousek
/ EN_ST-61A_08 / 25. 03. 2020
- 15 -
Push buttons, key switches or external radio receivers with potential-free contacts can be used as impulse switches.
G
impulse button
(
STA 11:
outside: term. 38/30, inside: term. 32/30)
Taster / Schalter
OPEN:
Via the impulse button terminals of the STA 11
only opening commands possible. It means that closing
the gate by giving an impulse on the terminals 38/30 or
32/30 is not possible.
(
Ampelsteuerung, Seite 7)
impulse button (e.g. key switch EPZ 1-2T)
Buttons/switches
Connections and adjustments
ST
A 11
2 P 1
38
30
32
30
2 P 1
impulse button
outside
impulse button
inside
STOPP button
(e.g. KDT-1N)
ST 61A
31
30
STOP-switch
(terminals 30/31)
Buttons / switches
•
when pressing the stop switch the gate stops in any desired position.
As stop switch a break contact has to be used.
If no stop switch is connected, terminals 30/31 have to be wire-bridged.
31
30
The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide
the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation!