tousek Rollco LWS125/X Installation Manual Download Page 2

- 2 - 

tousek

  /  E_ LWS-125/X_X40801104  /  22. 05. 2018

This manual is the sole property of the TOUSEK Ges.m.b.H. and may not be made available to competitors. All rights reserved. No part of it may be reproduced without our prior 

written permission. We will not accept liability for any claims resulting from misprints or errors. This edition of the manual replaces all earlier publications of the same.

 

Important warning and safety notes for installation and operation

•  These installation- and operating instructions form an integral part of the product “cantilever system”. They have been 

specifically written for professional installers trained and skilled in the trade and should be carefully read in their full length 

before carrying out the installation. After the installation this manual has to be handed over to the user.

• Installation, connection, adjustments, putting into operation, and servicing may only be carried out by trained 

professionals in full accordance with these installation- and operating instructions. Faulty assembling can 

cause severe injury and material damage.

•  The EU Machine Directive, laws and rules concerning the prevention of accidents, and laws and standards which are in 

force in the EU and in the individual countries have to be strictly followed.

• The TOUSEK Ges.m.b.H. cannot be held liable for any claims resulting from disregards of the laws and standards in force 

during the installation and operation.

•  The product may only be used in accordance with its original purpose, for which it has been exclusively designed, and 

which is described in these installation and operating instructions. The TOUSEK Ges.m.b.H. rejects any liability if the 

product is used in any way not fully conforming to its original purpose as stated herein.

• The packaging materials (cardboard, plastic, EPS foam parts and filling material etc.) have to be properly disposed of in 

 

accordance with the applying recycling- and environmental procection laws. They may be hazardous to children and 

therefore have to be stored out of children´s reach.

•  Before beginning with the installation the installer has to make sure that all mechanical components of the gate facility, like 

carrier profile/rail, gate frame and panels, guiding elements etc. are sufficiently supportive and resistant for the purpose 

of gate automation. Check also whether the product has transport damages.

•  After installation the proper function of the gate facility has to be checked!
•  Place warning signs and notes of the valid regulations to indicate danger areas.

•  Children have to be instructed, that the gate facility as well as the belonging parts may not be used improperly,  

e.g. for playing.

•  Only original spare- and replacement parts may be used for repair of the product.
•  The TOUSEK Ges.m.b.H. rejects any liability for claims resulting from usage of the product in combination with compo-

nents or devices which do not fully conform to the applying safety laws and rules.

•  The installer has to supply to the user all instructions relating to the safe operation of the gate facility. The installation 

and operating instructions also have to be handed over to the user.

 Maintenance

According to the frequency of actuation, but at least once a year, we recommend to carry out the following
maintenance works:
• Check if the rolling gears are standing in-line.
• Check if the gate is smooth running without jamming.
• Check the upper gate guiding.
• Check the assembly screws.
• Check if the door runs correctly into the guide-in bracket resp. guide-in fork bracket.

• Clean and sligthly grease the tread in the inside of the profile.

 

ATTENTION: blocking of the gate 

(see page 9) !

•  Firmly bolted mechanical stops prevent the running of the sliding gate on the rolling gears, when in OPEN or 

CLOSED position!

•  Examples of fixed limit stops as safety devices:
  (1) Guide-in bracket, (2) counter pillar, (3) transverse bore and  through screw (M12) in the profile

Summary of Contents for Rollco LWS125/X

Page 1: ...Installation manual Steel cantilever system Rollco LWS 125 X...

Page 2: ...e to be properly disposed of in accordance with the applying recycling and environmental procection laws They may be hazardous to children and therefore have to be stored out of children s reach Befor...

Page 3: ...and guarantees even with maximum load and big and heavy gates a smooth and reliable gate movement The adjusting bolts on the rollers prevent a tilting effect from load capacity changes during gate mov...

Page 4: ...ngtothestaticrequirements Load through wind The calculation of the cantilever system is based on a gate with bars or lattice No wind impermeable materials may be used as gate filling The measurements...

Page 5: ...width 9100 12000 2250 60kg m NOTE total length L profile length 10mm The track LWS 125 X is available in the following stock lengths 7 100 8500 10 000 and 12 000mm Em support length entrance width DL...

Page 6: ...rming tube correct positioning and then weld bolt the track with the gate bodywork Version through bolts 2a Connection of track with frame Mounting Bolt on mounting Legend 1 track 2 forming tube as re...

Page 7: ...sition of sloted holes L1 L4 now slide the cantilever track with the gate onto the rolling gears If necessary it is possible to make readjustments height adjustment or adjustment in sloted holes L1 L4...

Page 8: ...be effected along the channel B in the according gaps then cut thread M8 for mounting of gear rack into track profile check the installation of the gear rack in the corresponding sliding operator manu...

Page 9: ...le with bolts K Rubber bumper must show in direction of the rolling gear see picture K K A Important Limit stops A must be installed 3 3 rolling gears ATTENTION blocking of the gate Firmly bolted mech...

Page 10: ...WS 125 End plate with roller Rollco LWS 125 End plates Rollco LWS 125 Guide in bracket Rollco LWS 125 We reserve the right to change dimensions and technical specifications without prior notice 150 12...

Page 11: ......

Page 12: ...at Tousek GmbH Germany D 83395 Freilassing Traunsteiner Stra e 12 Tel 49 8654 77 66 0 Fax 49 8654 57 196 info tousek de Tousek Benelux NV BE 3930 Hamont Achel Buitenheide 2A 1 Tel 32 11 91 61 60 Fax 3...

Reviews: