background image

Simply make, spray, wipe or mop.

The solution will disinfect all hard surfaces and fabrics, killing up to 
99.999% of germs.

And with a gentle pH of between 7.8  and 8.5 it’s a non-aggressive cleaner 

too, leaving a smear-free finish on glossy surfaces without any chemical 

residue.

Use it anywhere

. There’s no need for one cleaner for the bathroom and 

another for the kitchen – and use it liberally as it’s virtually free.

It’s ready to use

 - so don’t dilute it or mix it with chemicals as it’s made at 

the perfect concentration.

It’s great for daily cleaning,

 and can be used as part of a deep clean for 

disinfecting areas, but it’s not a heavy degreaser or descaler. 

No special equipment is needed

 – use whatever cloths, bottles and mops 

you normally use, again and again as we’re into reusing not wasting! But 

for best results use microfibre.

Once you’ve run out

 – or after seven days when the solution reverts to 

slightly salty water – you simply make more.

Think of it as a multipurpose disinfectant 
cleaner. 

10 

Summary of Contents for eco worktop

Page 1: ...e your own multipurpose disinfectant cleaner that kills up to 99 999 of germs 1 litre Welcome to Our mission is to help workplaces become more sustainable by adopting an eco friendly way to clean that won t cost the earth toucan eco worktop ...

Page 2: ...Introduction 3 What s included 4 How it works 5 How to operate 6 How to use 8 1 year warranty 12 Product specification 13 Safety instructions 14 Troubleshooting 15 Contents 2 ...

Page 3: ...e use plastic bottles they are supplied in To make simply fill the container with tap water normal salt then activate which takes five minutes Then spray wipe or mop any surface including glass and fabrics For stains spray and leave to soak Can be used as a deodoriser Certified to EN 1276 and 13697 EU Biocide food safe and non toxic the solution contains 99 9 water hypochlorous acid and sodium hyp...

Page 4: ...ttle of salt to get you started The bottle is designed to atomise the solution into a mist like spray for maximum coverage and includes a kinetic continuous spray action What s included 1 4 8 2 5 9 3 7 6 10 11 1 6 7 8 9 10 11 4 5 2 3 Lid Base unit Adapter plug Jug Button light Salt Electrode Adapter Atomiser spray bottle Salt spoon 2g Stirring rod ...

Page 5: ...is cell This recombines the naturally occurring elements of hydrogen oxygen and chloride into hypochlorous acid HOCl an effective disinfectant and sodium oxygen and chloride into sodium hypochlorite NaOCl at a concentration and mild pH level that acts as a gentle cleaning agent After 7 days the solution reverts to slightly salty water You simply make more 5 ...

Page 6: ...l flash and beep the jug will light up blue and bubbles appear as electrolysis begins Add 2g of table salt that s a flat measure using the measuring spoon provided No more or less as this affects the electrolysis If too much salt is added rinse out the jug and start again Do not use rock salt After 5 minutes the base beeps blue jug and white button lights stay on and solution stops bubbling It s n...

Page 7: ...eep and lights flash twice Use the solution to safely spray wipe or mop any surface clean and germ free It can also be used as a deodoriser by killing the germs that creates the smell Please follow these steps otherwise your unit may shutdown for 3 minutes to reset After use rinse the jug in cold water carefully wipe inside and leave to dry Do not touch the electrode guard Always use the adapter a...

Page 8: ...e strong degreasers and descalers Simply spray wipe or mop any surface including glass and fabrics Spray wipe or mop Apply as a mist And repeat It also works as a deodoriser and you can apply it as a mist for disinfecting large areas Once you ve run out or before the solution reverts to salty water you simply make more 8 ...

Page 9: ...24 7 5 Washroom 4 3 Textiles carpets 2 Stainless steel windows glass 1 Surfaces equipment 2 5 2 2 3 3 3 1 1 2 2 1 1 1 4 4 9 ...

Page 10: ... s virtually free It s ready to use so don t dilute it or mix it with chemicals as it s made at the perfect concentration It s great for daily cleaning and can be used as part of a deep clean for disinfecting areas but it s not a heavy degreaser or descaler No special equipment is needed use whatever cloths bottles and mops you normally use again and again as we re into reusing not wasting But for...

Page 11: ... soaked microfibre or spray mopping And it s fine to spray alongside a bucket of hot water if that s what you re used to It s also great as a deodoriser it s not designed to mask smells as it s pretty much fragrance free but does kill the bacteria that causes the smell And as it s hypoallergenic you can happily spray away The range Toucan Eco Worktop Toucan Eco Active Toucan Eco Active Plus Toucan...

Page 12: ...ll not be warranted if the user instructions are not followed resulting in Corrosion or overheating of the electronics or terminals due to not cleaning and drying before use Overheating of electronics and terminals due to repeated activations without allowing for the cooling off period as specified in the user manuals Damage caused by using dirty or unfiltered water Warranty period The products ar...

Page 13: ...Cl and sodium hypochlorite NaOCl Concentration 80 to 100ppm free available chlorine pH 7 8 to 8 5 Time 5 mins Dispense Jug DC adaptor Input AC 100 240V Output DC 9V 3A Power consumption Rated 27w Size Base 104mm x 104mm x 70mm Jug 112mm x 160mm x 251mm Spray bottle 52mm x 80mm x 247mm Weight Base 213g Jug 360g Spray bottle 95g Materials Base PC SAN Jug ABS Spray bottle PP PET Certifications EN 127...

Page 14: ...evert to salty water after seven days Use water temperature between 5 C and 35 C Do not use purified ground or polluted water Do not keep the electrolysed water in a drinking bottle or keep it in the fridge in case it s mistaken for drinking water After each activation make sure the device is allowed 3 minutes to cool down between uses otherwise the electronics and terminals may overheat Store the...

Page 15: ...ce will not run for the next 3 minutes for safety reasons Excessive operation also causes safety turn off Please remove the plug from socket outlet and cool down for about 20 minutes Upon pressing the start button there is just a beep the LED is immediately turned off and device won t work Did you add too much salt If too much salt is used or not dissolved completely the device will not run for sa...

Page 16: ...16 twitter com toucan_eco instagram com toucan_eco facebook com toucaneco Visit website Scan QR code to www toucaneco co uk ...