6

7

Set-up drawing

Controller

0ver 200

Warning

Install the controller taller than F.L. by 200mm(Otherwise, 

 the strainer on the bracket will be inaccessible for cleaning.)

Do not bend the Flexible tube at acute angle. Also, do not

   bend it at the portion near the hexagon nut.

Installation procedure

  Piping

Be sure to thoroughly flush away any
foreign matter such as dirt and sand 
trapped in the water supply pipe.

  Remove the stop valve.

Close the source stop valve.

Warning

Do not use the stop 
valve with strainer 
supplied with   
Automatic Faucet.

Loosen the two screws on the front

    cover with the allen wrench.

Pull and open the controller cover

    to the direction as shown right.

Remove the quick fastener and then
remove the stop valve.

Pull

Controller 
cover

Quick 
fastener

Stop valve 
with strainer

Position the controller.

Connect the flexible tube and the 

    controller to the Optional bracket 
    tentatively.

Determine the location of the 

    controller and mark holes of the
    Optional bracket.

Detach the flexible tube and the

    controller.

 Flexible tube

  Controller

Marking holes

Warning

Be sure to place the controller with 
its outlet at the top. 

Otherwise, the water will come into 
the controller resulting in product 
malfunction.

Mount the optional bracket on the wall.

After drilling the wall,tighten
the Optional bracket with 
tapping screws. 

Tapping screws

Optional bracket

Connect the flexible tube to the Optional bracket .

other optional parts

Flexible tube

Packing

Optional 
bracket

Warning

Never fail to attach the Packing.

Controller   

 Quick fastener  

Optional bracket

Install Automatic Faucet.

Refer to the Instruction manual of 
Automatic  Faucet on the subseguent procedure. 

Cleaning the strainer

Close the stop valve.

Connect the controller to the
Optional bracket.

Remove the strainer cover 
with open-close tool.

Pull out the strainer and clean 
it with a blush.

Put the strainer back in its 
place.

Reopen the stop valve full.

Strainer  

Strainer cover

    Open-close tool

Connect the controller to the Optional bracket. 

Important

  Optional bracket

Outlet of controller 

G1/2

IN

Attach it with a quick fastener.

Summary of Contents for TN74-2X

Page 1: ...42 2003 5 施工 取扱説明書 TN74 2X 自動水栓用取替脚 商品の機能が十分に発揮されるように この施工説明書の内容にそって正しく取り付けてください 工事店様へのお願い この施工 取扱説明書は必ずお客様にお渡しください 自動水栓 アクアオート の機能部を設置する際に配管や 配線が障害になり止水栓に取り付けできない場合 又は商 品が正しい向きに取り付かない場合にご利用ください 自動水栓 機能部 施工 ...

Page 2: ...必ず機能部接続口が上になるように 固定してください 水が浸入し 不具合の原因になります フィルター ふた 開閉工具 機能部接続口 取替脚 自動水栓 機能部 6 7 必要別売品 給水 G1 2 ...

Page 3: ...et Tapping screw Warning Please select adequate Flexible tube according to the site Stop valve Flexible tube resin tube Other optional parts Flexible tube copper tube TEL7 Atype TEL7 Btype Water supply connection Applicable items Specifications Before installation This is Installation and instruction manual for Optional bracket TN74 2X used for Automatic Faucet Single Faucet In case the controller...

Page 4: ... mark holes of the Optional bracket Detach the flexible tube and the controller Flexible tube Controller Marking holes Warning Be sure to place the controller with its outlet at the top Otherwise the water will come into the controller resulting in product malfunction Mount the optional bracket on the wall After drilling the wall tighten the Optional bracket with tapping screws Tapping screws Opti...

Reviews: