Before installation,
please wash out dirt, sand, etc., in the water supply pipe thoroughly.
Connect the joint for the check valve with the filtering screen
Remove the filtering screen from the
joint for the check valve and put it into
the angle valve for water supply.
Screw the joint for the check valve
into the angle valve for water supply.
Joint for check
valve
Filtering screen
Angle valve for
water supply
Fix the faucet temporarily
Insert the faucet into the installation
hole of the earthenware.
Orient the faucet towards the water
outlet, and screw the hexagon nut
to fix the faucet temporarily.
Please try not to entangle the water supply
pipe with the connecting line of the sensor.
Faucet location
Drainage hole
Faucet part
Center of basin
Hexagon nut
Installation steps
Make sure the
indicator light of the
sensor is illuminated
Water supply temperature:
60°C~85°C
Remove the cover of
the functional part
Install the functional
part
Install the cover of the
functional part
Fix the faucet temporarily
Fix the faucet
Cold water
Hot water
Insert the connecting line of the
sensor
Clean the water supply pipe
Connect the joint for the
check valve with the filtering
screen
Insert the power
plug (AC type)
Clean the water supply pipe
Temperature
adjusting handle
Important
Before installation
1. Check the water supply pressure
z
The water supply pressure is from 0.05 to 1.0MPa. Please use it within this pressure range.
z
When the water supply pressure exceeds 1.0MPa, please use the reducing valve to reduce the
pressure to 0.2MPa.
We suggest you use the water pressure of about 0.2MPa, which is more comfortable during use.
z
The cold water supply pressure must be higher than or equal to the hot water supply pressure.
2. Check the hot water supply temperature
z
To avoid scalding due to mis-operation, the hot water supply temperature should not exceed 85°C.
3. For layout of pipes and lines
z
Too long hot water pipes from the water heater may cause heat loss. Please calculate the shortest
distance to install the hot water pipes and wrap them with thermal insulation materials.
4. Others
z
Please try not to damage the surface of the sensor.
z
Aqua-auto is only used indoors. Please do not install it outdoors.
z
Converters or other machines using infrared rays may cause misoperation.
z
Because this product is checked for water inlet before packaging, there may be water in this
product, and it is not a problem.
z
When it is necessary to use drainage components, angle valves for water supply, components to
install reversed hooks, brackets, frames, etc., matching the earthenware installed, please confirm
related construction materials and purchase them separately.
Standard installation drawing
Outlet 385 ~ 405
Inlet 350
DLE124BSK
DLE124BE
Product view
Faucet
Sensor
Connecting line
Functional
part
Water
supply hose
Hexagon nut
Temperature
adjusting handle
Faucet
Sensor
Connecting line
Functional
part
Water
supply hose
Hexagon nut
Temperature
adjusting handle
Accessories
Alkaline dry cells
(2 AA cells)
(* for DLE127BSK)
Hex wrench
Knob switch Operation manual
Construction
manual
Product model and specification
Do not install the filtering screen
inversely.
Caution
Connect the water supply
pipe with the joint for the
check valve
Caution
5
7
8
6
Hot water
supply hose