Before installation, 

please wash out dirt, sand, etc., in the water supply pipe thoroughly.

Connect the joint for the check valve with the filtering screen

  Remove the filtering screen from the 

joint for the check valve and put it into 

the angle valve for water supply.

  Screw the joint for the check valve 

into the angle valve for water supply.

Joint for check 

valve

Filtering screen

Angle valve for 

water supply

Fix the faucet temporarily

  Insert the faucet into the installation 

hole of the earthenware.

  Orient the faucet towards the water 

outlet, and screw the hexagon nut 

to fix the faucet temporarily.

Please try not to entangle the water supply 

pipe with the connecting line of the sensor.

Faucet location

Drainage hole

Faucet part

Center of basin

Hexagon nut

Installation steps

Make sure the 

indicator light of the 

sensor is illuminated

Water supply temperature: 

60°C~85°C

Remove the cover of 

the functional part
Install the functional 

part

Install the cover of the 

functional part

Fix the faucet temporarily

Fix the faucet

Cold water

Hot water

Insert the connecting line of the 

sensor

Clean the water supply pipe

Connect the joint for the 

check valve with the filtering 

screen

Insert the power 

plug (AC type)

Clean the water supply pipe

Temperature  

adjusting handle

Important

Before installation

1. Check the water supply pressure

„

z

The water supply pressure is from 0.05 to 1.0MPa. Please use it within this pressure range.

„

z

When the water supply pressure exceeds 1.0MPa, please use the reducing valve to reduce the 

pressure to 0.2MPa.  

We suggest you use the water pressure of about 0.2MPa, which is more comfortable during use.

„

z

 

The cold water supply pressure must be higher than or equal to the hot water supply pressure.

2. Check the hot water supply temperature

„

z

To avoid scalding due to mis-operation, the hot water supply temperature should not exceed 85°C.

3. For layout of pipes and lines

„

z

Too long hot water pipes from the water heater may cause heat loss. Please calculate the shortest 

distance to install the hot water pipes and wrap them with thermal insulation materials.

4. Others

„

z

Please try not to damage the surface of the sensor.

„

z

Aqua-auto is only used indoors. Please do not install it outdoors.

„

z

Converters or other machines using infrared rays may cause misoperation.

„

z

Because this product is checked for water inlet before packaging, there may be water in this 

product, and it is not a problem.

„

z

When it is necessary to use drainage components, angle valves for water supply, components to 

install reversed hooks, brackets, frames, etc., matching the earthenware installed, please confirm 

related construction materials and purchase them separately.

Standard installation drawing

Outlet 385 ~ 405

Inlet 350

DLE124BSK

DLE124BE

Product view

Faucet

Sensor 

Connecting line

Functional 

part

Water 

supply hose

Hexagon nut

Temperature 

adjusting handle

Faucet

Sensor 

Connecting line

Functional 

part

Water 

supply hose

Hexagon nut

Temperature 

adjusting handle

Accessories

Alkaline dry cells 

(2 AA cells) 

(* for DLE127BSK)

Hex wrench 

Knob switch  Operation manual 

Construction 

manual

Product model and specification

Do not install the filtering screen 

inversely.

Caution

Connect the water supply 

pipe with the joint for the 

check valve

Caution

5

7

8

6

Hot water 

supply hose

Reviews: