Select the security level:
0=No security in effect
1=Setpoint range limited
2=1+ locked in current
mode.
3=2 + prohibits setpoint
changes
Adjust the minimum
allowable cool setpoint
when security is in effect.
(35 - 99 )
Press
MODE
Press
MODE
Press the HUMIDITY button to leave the Setup screens. If no buttons are
pressed, the display will leave the setup screens after 30 seconds.
HUMIDITY
Press
When a security level has been programmed, the thermostat will allow
limited adjustment to the setpoints (
steps # 6 and 7
) and, in security
levels 2 and 3, the thermostat will be locked into the current mode (off,
heat, cool, or auto). To disable the security feature, program step #5
to 0; this will cause steps # 6 and 7 not to appear.
Page 7.4
Programming a Security Level
Programming a Security Level
0
Setup
5
H
EAT
80
Setup
6
C
OOL
55
Setup
7
Adjust the maximum
allowable heat setpoint
when security is in effect.
(35 - 99 )
Step #6 appears only
if step #5 is not 0.
Step #7 appears only
if step #5 is not 0.
TOTALINE
Note: Press the
MODE
button momentarily
to move through the
setup screens. Press
and hold the
MODE
button to move back-
wards through the
setup screens.
7
HUMIDITY
MODE
MODE
Press the MODE button. While holding
the MODE, press the HUMIDITY button
to enter Setup screens.
Press the MODE button repeatedly
until this setup screen appears.
Summary of Contents for P374-2 700