SETTINGS – OUTDOOR EQUIPMENT STAGES
10
DEFINITION
DEPENDENCIES
FUNCTION
Pressing the Outdoor Equip Stages field in the “System
Settings Screen” will invoke the “Outdoor Equip Stages
Screen” which allows for selection of the number of
stages for the outdoor equipment being used from 0 to 2.
Pressing the Left Arrow Button or the Right Arrow Button
will scroll through the available number of outdoor
equipment stages, which is displayed in the center of the
screen. Once the correct outdoor equipment stages are
selected, pressing the Save Button will save the selection
into non-volatile memory. Pressing the Defaults Button
will load the default outdoor equipment stages of “1” (the
user will still need to Save or Cancel this setting).
Pressing the Cancel Button will navigate back to the
“System Settings Screen”.
The option of “0”
OUTDOOR
EQUIPMENT STAGES
is only available if the
OUTDOOR
EQUIPMENT TYPE of
NONE is selected.
The numbers of stages chosen
defines the number of HP or A/C
cooling stages that are present in
the outdoor equipment. The
numbers of stages chosen also
defines the number of HP heating
stages that are present in the
outdoor equipment if the OUTDOOR
EQUIPMENT TYPE of HP is
selected.