P340 Series
570-219
9
69-2268—03
0500
Furnace filter
change reminder
0 Off
1 10-day run time (about 1 month)
2 30-day run time (about 3 months)
3 60-day run time (about 6 months)
4 90-day run time (about 9 months)
5 120-day run time (about 1 year)
6 365-day run time (about 3 years)
0510
Humidifier pad
change reminder
0 Off
1 90 calendar days
2 180 calendar days
3 365 calendar days
0520
UV lamp change
reminder
0 Off
1 365 calendar days
0530
Early Recovery
1 On
** See page 11
0 Off
0540
Program periods
4 4 program periods (Wake, Leave, Return, Sleep)
2 2 program periods (Wake, Sleep)
0580
Compressor
protection
5 5 minute compressor off time
** See page 11
[Other options: 0, 2, 3 or 4-minute off time]
0600
Heat temperature
range stop
90 Max. heat temperature setting is 90°F (32°C)
[Other options: 40-89°F (4.5°C to 31.5°C)]
0610
Cool temperature
range stop
50 Min. cool temperature setting is 50°F (10°C)
[Other options: 51-99°F (11°C to 37°C)]
0640
Clock format
12 12-hour time (i.e., “3:30 pm”)
24 24-hour time (i.e., “15:30”)
0650
Extended fan
timer (heat)
0 Off
90 Fan runs for 90 seconds after call for heat ends
0660
Extended fan
timer (cool)
0 Off
90 Fan runs for 90 seconds after call for cooling ends
0670
Keypad lock
0 Keypad unlocked (fully functional)
1 Partially locked (access to temperature settings only)
2 Fully locked
0680
Heat temperature
control
2 Standard temperature control (recommended)
1 Choose if room is warmer than set temperature
3 Choose if room does not reach set temperature
0690
Cool temperature
control
2 Standard temperature control (recommended)
1 Choose if room is cooler than set temperature
3 Choose if room does not reach set temperature
0700
Temperature
display offset
0 Thermostat displays actual room temperature
[Other options: -3, -2, -1, 1, 2, 3°F offset (-1.5°C to 1.5°C)
0710
RESET
0 No reset
1 Reset installer options & program schedule to factory
default (only date and time settings are retained)
Installer setup