8
5.6 Print
5.6.1 Under the normal weighing mode, when the scale reading is stable, press “
” key to output the data
via RS232 interface as following format.
5.6.2 Print Out format (ref. to 10.8, the scale is connected to a PC and the PC is a HOST device)
5.7 To count when the average piece weight is known but not stored into memory (Input the piece weight
directly)
5.7.1 Under the normal wei
ghing mode, press “
PcWt
” to enter this mode. The WEIGHT window displays the
current total weight, the COUNT window displays “PCwt” (Piece Weight), the PIECE WEIGHT window
displays the input piece weight.
5.7.2 Press numerical keys 0
~
9 and clear key to input the piece weight.
5.7.3 Press
ENTER
key to save and record the input, or press
EXIT
key to exit this mode and return back to the
normal weighing and counting mode.
5.7.4 Note
:
The piece weight must be over or equal to the required minimum piece weight. If the input piece weight is
less than the above range, the data will be not accepted and the scale will be reminded by “
Lo.PCwt
”
when ENTER key be pressed.
5.8 To count when the average piece weight is unknown and not stored into memory (Input the samples
quantity to calculate the piece weight)
5.8.1 Under the normal weighing mode, if the quantity of objects loaded onto the platter is known, press
PCS
key to enter into this mode. The WEIGHT window displays the weight, PIECE WEIGHT window displays
“
SPL.PCS
” (Sample Pieces) and COUNT window displays the input quantity.
5.8.2 Press numerical keys 0
~
9 and clear key to input the know quantity.
5.8.3 Press
ENTER
key to save and record the input, or press
EXIT
key to exit this mode and return back to the
normal weighing and counting mode.
5.8.4 Note
:
The piece weight calculated by known quantities and weight must be over or equal to the minimum piece
weight limit. If the input piece weight is less than the above range, the data will be not accepted and the
s
cale will be reminded by “
Lo.SPwt
” when
ENTER
key be pressed, then it back to use original piece
weight.
5.10 To store information into memory ID (Set UTPs)
Whether TARE and Average Piece Weight are known or unknown.
Start:
5.10.1 P
ress “
ST.UTP
” key to enter this mode. The WEIGHT window displays “
Set.UTP
” (This means the scale is
under piece weight setup and storing mode), The COUNT window displays “
Addr.
” (This means the unit
address of item needs to be set, the address range is 1-256), the PIECE WEIGHT window displays the
input
Addr
data.
5.10.2
Input address:
Use numerical keys 0
~
9
to input the address to be used for this item. Press “
ENTER
” key
to confirm and go to the next step, or press
EXIT
key to exit this mode and return back to the normal
weighing and counting mode.
5.10.3
Select weight unit:
The PIECE WEIGH
T window shows “kg” or “lb”, which means the unit of the stored
piece weight is kg or lb
,
the COUNT window shows “Unit”
5.10.4 Use
UNIT
key to choose kg or lb, press
ENTER
key to confirm and go to the next step, or press
EXIT
key to