14
10.6
RS-232
connects between scale and host
:
Scale
--------------------------------Cable
(
9 pins
)
------------------------
Host
(Computer)
DB9 (Female) ----------- DB9 (Male Connector) ------------------------ Host connector
PIN2 TXD----------------------2---------------------2----------------------------PIN2 RXD
PIN3 RXD----------------------3--------------------3-----------------------------PIN3 TXD
PIN5 GND---------------------5---------------------5-----------------------------PIN5 GND
PIN4 DSR---------------------4---------------------4-----------------------------PIN4 DTR
PIN6 DTR---------------------6---------------------6-----------------------------PIN6 DSR
PIN7 CTS---------------------7---------------------7-----------------------------PIN7 RTS
PIN8 RTS---------------------8---------------------8-----------------------------PIN8 CTS
PIN1 NC----------------------1---------------------1------------------------------PIN1 NC
PIN9 NC----------------------9---------------------9------------------------------PIN9
Note: The PIN4, PIN6, PIN7 and PIN8 are shorted in scale!
Scale
---------------------------
Printer
DB9 connector --------------- (printer supplied connector XX)
PIN2 TXD -------------------- Printer RXD
PIN3 RXD -------------------- Printer TXD
PIN5 GND -------------------- Printer GND
11. Date and time setting
11.1 Under the normal working mode, press and hold
5
and
ON/OFF
key for more than 3s to enter into this mode.
In this mode, you can set the system date and time.
(
Note: the date and time in scale will be lost after the
scale power off if no Real Time Clock module is installed
)
11.2 After entering into this mode, the WEIGHT window will display “
SEtuP
”, the PIECE WEIGHT window will
display “
dAtE
”(date) and the COUNT window will display the current date xx.xx.xx (format
:
YY.MM.DD).
11.3 Use the numerical keys to input the date
(
format
:
YY.MM.DD
)
,
use
Enter
key to confirm and go to the time
setting mode.
11.4 Then the weight window displays “
SetuP
”
,
the PIECE WEIGHT displays
“
timE
” (time) and the total price
window displays the current time xx.xx.xx.
11.5 Use the numerical keys to input the time
(
Format
:
hh.mm.ss
)
,
press
Enter
to confirm the input and exit this
mode.
12. ID setting
12.1 Under the normal working mode, press and hold
6
and
ON/OFF
key for more than 3s to enter this mode. In
this mode, you can set ID code.
12.2
After entering this mode, the WEIGHT window displays “
SEtuP
”
,
the PIECE WEIGHT window displays “
Id
”
and the COUNT window displays Id code(the default Id code is 000000) xxxxxx.
12.3 Use the numerical keys to input ID code
,
then press
ENTER
key to confirm the input and exit this mode.