Batch:
Batch mode is a special testing mode, which only requires the user
to click Start once to test a number of cables. Once started, the Advanced
Cable Tester will remain active and test cables as they are inserted. The
pass/fail status of the cable will be indicated by the LEDs on the Advanced
Cable Tester Hardware until the cable is unplugged. The test results will be
stored on the device and can be retrieved through the web interface.
Continuous:
Continuous mode is a special testing mode which will
continuously run tests on a single cable until stopped, with a 500 ms delay
between test runs. This test mode is particularly useful for burn-in or
environmental testing of cables.
Start:
Click to start a test, using the currently selected pro
fi
le.
The Results section provides a list of the test results available on the Advanced Cable
Tester, and a high-level summary of the test outcomes. Clicking on any result will take
the user to the detailed test results view. If there are more than 10 reports available, then
use the and buttons to navigate to the previous or next page, and the and
buttons to go to the
fi
rst or last pages. Additionally, it is possible to download and remove
test results by selecting them in the list and clicking on the (download) or (delete
selected) buttons. The summary test results shown in the current on-screen list can be
printed by clicking on the
(print) button. Finally, all stored test results can be
downloaded by clicking the
(download) button, or deleted by clicking the (delete all)
button.
4.2 Test Pro
fi
les and Pro
fi
le Con
fi
guration
The Advanced Cable Tester includes an Auto-Detect pro
fi
le, several preset Type-C
pro
fi
les, and the ability to create custom pro
fi
les. The preset pro
fi
les [marked with an
* (asterisk)] cannot be modi
fi
ed or deleted; they can be copied and exported.
Advanced Cable Tester User Manual v1.13.001