Controller functions
Page 34
RES-409
Address
(hex)
Value
(dec)
Meaning
0000
0001
0002
0003
0…T
max
0…T
max
0…T
max
0…T
max
Current set point 0 (in °C)
Current set point 1 (in °C)
Current set point 2 (in °C)
Current set point 3(in °C)
0004
-20…T
max
Current actual value (in °C)
0005
(
Full current controller status
0006
3 digits (BCD
coded)
Digits 1…3 of 6-digit controller number
0007
3 digits (BCD
coded)
Digits 4…6 of 6-digit controller number
0008
0…40
Current calibration temperature (in °C)
0009
(
Acknowledgment message (current actual value with reduced controller status)
000A
As of
Feb. 2007:
3…99
Up to
Jan. 2007:
3…20
Current upper temperature tolerance band limit
000B
0…5 (
Current heatsealing band alloy/temperature range
The following CAN messages are only available on controllers manufactured as of February 2007:
000C
0…65535
Current fault and AUTOCAL status
(
section 10.4.3 "Fault / AUTOCAL status (as of February 2007)" on page 37)
000D
0…2
Hold mode: 0=OFF, 1=ON, 2=2 seconds
000E
0, 1
AUTOCOMP status: 0=OFF, 1=ON
000F
0…500
Maximum set point
0010
0…999
Software revision
0011
0…99
Software version (default value: 00)
0012
400…4000
Current variable temperature coefficient (TCR in ppm/K)
0013
0…2
"Temperature OK" bit: 0=OFF, 1=active if set = act, 2=active if set = act with latch
function
0014
3…99
Lower temperature tolerance band limit
0015
3…99
Upper temperature tolerance band limit
0016
0, 1
Temperature diagnosis: 0=OFF, 1=ON
0017
0…99
Temperature diagnosis delay in 0.1s
0018
0…999
Heatup timeout in 0.1s
0019
17…30
Measuring impulse length in 0.1ms
001A