Requirements for electric connection
Safety precaution
Grounding requirement
1. Must follow the electric safety regulations when installing the unit.
$FFRUGLQJWRWKHORFDOVDIHW\UHJXODWLRQVXVHTXDOL¿HGSRZHUVXSSO\FLUFXLWDQG
air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
'RQRWSXWWKURXJKWKHSRZHUEHIRUH¿QLVKLQJLQVWDOODWLRQ
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
VHUYLFHDJHQWRUVLPLODUO\TXDOL¿HGSHUVRQVLQRUGHUWRDYRLGDKD]DUG
8. The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
7KHDLUFRQGLWLRQHULVWKH¿UVWFODVVHOHFWULFDSSOLDQFH,WPXVWEHSURSHUO\
JURXQGLQJZLWKVSHFLDOL]HGJURXQGLQJGHYLFHE\DSURIHVVLRQDO3OHDVHPDNH
sure it is always grounded effectively, otherwise it may cause electric shock.
7KH\HOORZJUHHQZLUHLQDLUFRQGLWLRQHULVJURXQGLQJZLUHZKLFKFDQWEHXVHG
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
DOOSROHVVKRXOGEHFRQQHFWHGLQ¿[HGZLULQJ