DC Inverter U-match Series Duct Type Unit
6
Fig. 3.1
(4). Install the unit where the drain pipe can be easily installed.
(5). The space from the unit to the ceiling should be kept as much as possible so
as for more convenient service.
3.2.2 Outdoor Unit
①
.
Install the unit where it will not be tilted by more than 5°.
②
.
During installation, if the outdoor unit has to be exposed to strong wind, it must be fixed securely.
(1). If possible, do not install the unit where it will be exposed to direct sunlight. (If
necessary, install a blind that does not interfere with the air flow.)
(2). Install the outdoor unit in a place where it will be free from getting dirty or
getting wet by rain as much as possible.
(3). Install the outdoor unit where it is convenient to connect the indoor unit.
(4). Install the outdoor unit where the condensate water can be drained out freely
during heating operation. Do not place animals and plants in the path of the
warm air.
(5). Take the air conditioner weight into account and select a place where noise
and vibration are small.
(6). Install the outdoor unit where is capable of withstanding the weight of the unit
and generates as less noise and vibration as possible.
(7). Provide the space shown in Fig. 3.2, so that the air flow is not blocked. Also for
efficient operation, leave three of four directions of peripheral constructions
open.