WX9 ASD Installation and Operation Manual
129
Heavy-Load Torque During Acceleration in the Reverse
Direction
Program
Motor
Crane/Hoist Load
During reverse acceleration, this parameter establishes the threshold torque
level that is used to determine if the
Light-Load High-Speed
(
) operation
may engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F339
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Deceleration in the Reverse
Direction
Program
Motor
Crane/Hoist Load
During reverse deceleration, this parameter establishes the threshold torque
level that is used to determine if the
Light-Load High-Speed
(
) operation
may engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F340
Parameter Type —
Numerical
Factory Default —
100
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Frequency for Automatic High-Speed Operation at Light-
Load
Program
Motor
Crane/Hoist Load
This parameter establishes the speed that the ASD will ramp to when operating
in the
Light-Load High-Speed
mode.
Direct Access Number — F341
Parameter Type —
Numerical
Factory Default —
60
Changeable During Run —
Yes
Minimum — 30.00
Maximum — Upper-Limit Freq. (
Units — %