128
WX9 ASD Installation and Operation Manual
Light-Load High-Speed Operation Heavy-Load Detection
Time
Program
Motor
Crane/Hoist Load
While operating in the
Light-Load High-Speed
mode, this parameter
determines the length of time that a load exceeding the
Light-Load High-
Speed
operation criteria may exist before the
Light-Load High-Speed
mode is
terminated and normal operation resumes.
Direct Access Number — F334
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Switching Load Torque During Forward Run
Program
Motor
Crane/Hoist Load
While running forward, this parameter establishes the threshold torque level
that is used to determine if the
Light-Load High-Speed
) operation may
engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F335
Parameter Type —
Numerical
Factory Default —
50
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Acceleration in the Forward
Direction
Program
Motor
Crane/Hoist Load
During forward acceleration, this parameter establishes the threshold torque
level that is used to determine if the
Light-Load High-Speed
(
) operation
may engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F336
Parameter Type —
Numerical
Factory Default —
(ASD-Dependent)
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Deceleration in the Forward
Direction
Program
Motor
Crane/Hoist Load
During forward deceleration, this parameter establishes the threshold torque
level that is used to determine if the
Light-Load High-Speed
(
) operation
may engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F337
Parameter Type —
Numerical
Factory Default —
100
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Switching Load Torque During Reverse Run
Program
Motor
Crane/Hoist Load
While running in reverse, this parameter establishes the threshold torque level
that is used to determine if the
Light-Load High-Speed
) operation may
engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F338
Parameter Type —
Numerical
Factory Default —
50
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Summary of Contents for WX9 ASD
Page 2: ......
Page 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv WX9 ASD Installation and Operation Manual ...
Page 225: ......