Adjustment range

0.0-3200 (s)

0.0-3200 (s)

0: Linear, 1: S-pattern 1, 2: S-pattern 2

0: Linear, 1: S-pattern 1, 2: S-pattern 2

1: Acc/dec 1, 2: Acc/dec 2, 3: Acc/dec 3

0.0-       (Hz)

0-50 (%)

0-50 (%)

0.0-3200 (s)

0.0-3200 (s)

0: Linear, 1: S-pattern 1, 2: S-pattern 2

0.0-       (Hz)

0-        (Hz)

0-30 (Hz)

0-        (Hz)

0-30 (Hz)

0-        (Hz)

0-30 (Hz)

0: Reverse, 1: Slowdown Stop

0.5-10 (Hz)

0-        (Hz)

0-        (Hz)

0: Invalid, 0.1-600 (s)

0, 1, 2

List of parameters

 -       (Hz)

Title

Function

Adjustment range

Default setting

Preset-speed operation frequency 8

Preset-speed operation frequency 9

Preset-speed operation frequency 10

Preset-speed operation frequency 11

Preset-speed operation frequency 12

Preset-speed operation frequency 13

Preset-speed operation frequency 14

Preset-speed operation frequency 15 (Fire-speed)

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

 -       (Hz)

 -       (Hz)

 -       (Hz)

 -       (Hz)

 -       (Hz)

 

-

       (Hz)

 -       (Hz)

Title

Function

Adjustment range

Default setting

Dynamic braking selection

Dynamic braking resistance

Dynamic braking resistor capacity

0: Invalid, 1: Valid

1.0-1000 (

)

0.01-30.00 (kW)

0

* 1

* 1

* 1: Default values vary depending on the capacity.

Title

Function

Adjustment range

Default setting

Base frequency 2

Base frequency voltage 2

Torque boost value 2

Motor electronic-thermal protection level 2

Stall prevention level 2

25-500 (Hz)

50-330 (V)/50-660 (V)

0-30 (%)

10-100 (%/A)

10-199 (%/A), 200: Invalid

50/60

230/460/575

* 1

100

150

Title

Function

Adjustment range

Default setting

Acceleration time 2

Deceleration time 2

Acceleration/deceleration 1 pattern

Acceleration/deceleration 2 pattern

Acceleration/deceleration 1, 2, 3 selection

Acc/dec 1 and 2 switching frequency

S-pattern lower-limit adjustment amount

S-pattern upper-limit adjustment amount

Acceleration time 3

Deceleration time 3

Acceleration/deceleration 3 pattern

Acc/dec 2 and 3 switching frequency

10.0

10.0

0

0

1

0.0

10

10

10.0

10.0

0

0.0

Title

Function

Adjustment range

Default setting

Jog run frequency

Jog run stopping pattern

Panel jog run operation mode

             - 20.0 (Hz)

0, 1, 2

0: Invalid, 1: Valid

5.0

0

0

Title

Function

Adjustment range

Default setting

Jump frequency 1

Jumping width 1

Jump frequency 2

Jumping width 2

Jump frequency 3

Jumping width 3

0-        (Hz)

0-30 (Hz)

0-        (Hz)

0-30 (Hz)

0-        (Hz)

0-30 (Hz)

0.0

0.0

0.0

0.0

0.0

0.0

Title

Function

Adjustment range

Default setting

Priority selection (Both F-CC and R-CC are ON)

Starting frequency setting

Operation starting frequency

Operation starting frequency hysteresis

Time limit for lower-limit frequency operation

Reverse-run prohibition

1

0.5

0.0

0.0

0.1

0

0-2400 (s)

0: Invalid, 1: Valid

0.01-100.0

0.01-100.0

0.00-2.55

Title

Function

Adjustment range

Default setting

Logic output/pulse train output selection (OUT-NO)

Pulse train output function selection (OUT-NO)

Maximum numbers of pulse train

Inclination characteristic of analog output

Meter bias

0: Logic output, 1: Pulse train output

0-17 (Same as

                 )

500-1600(PPS)

0: Negative inclination, 1: Positive inclination 

0-100 (%)

0

0

800

1

0

Title

Function

Adjustment range

Default setting

PID control waiting time

PID control

Proportional gain

Integral gain

Differential gain

0

0

0.30

0.20

0

Title

Function

Adjustment range

Communication rate

Parity

Inverter number

Communication error trip time

Communication waiting time

Setting of master and slave for

communication between inverters

Communication command point 1 setting

Communication command point 1 frequency

Communication command point 2 setting

Communication command point 2 frequency

Selection of communication protocol 

Block write data 1

Block write data 2

Block read data 1

Block read data 2

Block read data 3

Block read data 4

Block read data 5

0, 1, 2, 3, 4

0, 1, 2

0-255

0: Invalid, 1-100 (s)

0-2 (s)

0, 1, 2, 3, 4

0-100 (%)

0.0-500.0 (Hz)

0-100 (%)

0.0-500.0 (Hz)

0, 1

0-5

0-5

0-10

0-10

0-10

0-10

0-10

3

1

0

0

0.00

0

0

0.0

100

60.0

0

0

0

0

0

0

0

0

Default setting

Title

Function

Adjustment range

Default setting

Stall prevention release mode

Small current detection current hysteresis

Small current trip/alarm selection

Small current detection current

Small current detection time

Detection of output short-circuit during start-up

Over-torque trip/alarm selection

Over-torque detection level

Over-torque detection time

Over-torque detection level hysteresis

Cumulative operation time alarm setting

Over-voltage stall protection level

Undervoltage trip/alarm selection

Trip at VIA low level input mode

Annual average ambient temperature

(parts replacement alarms)

0, 1

1-20

0: Alarm only, 1: Tripping

0-100 (%)

0-255 (s)

0, 1, 2, 3 

0: Alarm only, 1: Tripping

0-250 (%)

0-10 (s)

0-100 (%)

0-999.9

100-150 (%)

0, 1, 2

0: Invalid, 1-100 (%)

1, 2, 3, 4, 5, 6

0

10

0

0

0

0

0

150

0.5

10

610

*1

0

0

3

Title

Function

Adjustment range

Default setting

Prohibition of parameter change

Prohibition of frequency setting on the operation panel (         )

Panel operation prohibition (RUN/STOP keys)

Prohibition of panel emergency stop operation

Prohibition of panel reset operation

Prohibition of                

/ /             change

during operation

0: Permitted, 1: Prohibited

0: Permitted, 1: Prohibited

0: Permitted, 1: Prohibited

0: Permitted, 1: Prohibited

0: Permitted, 1: Prohibited

0: Permitted, 1: Prohibited

0

0

0

0

0

1

External connection input up/down setting parameters

Input from external contacts- UP response time

Input from external contacts- UP frequency step width

Input from external contacts- DOWN response time

Input from external contacts- DOWN frequency step width

Initial value of UP/DOWN frequency

Saving of changed value of UP/DOWN frequency

0.0-10.0 (s)

0.0-       (Hz)

0.0-10.0 (s)

0.0-       (Hz)

              (Hz)

0, 1

0.1

0.1

0.1

0.1

0.0

1

Torque up detailed setting parameter

Title

Function

Adjustment range

Default setting

Exciting current coefficient

Stall prevention control coefficient 1

Stall prevention control coefficient 2

Motor adjustment coefficient

Maximum voltage adjustment coefficient

Waveform switching adjustment coefficient

Starting current suppression function

100-130 (%)

10-250

50-150

0-200

90-120 (%)

0.1-14.0 (kHz)

0: Invalid, 1: Valid

100

100

100

* 1

104

0.2

0

Title

Function

Adjustment range

Default setting

11

Parameters for setting functions that cannot be fulfilled by basic parameters. 

Output terminal functions list

Function No.

Function

Frequency lower limit

Frequency upper limit

Low-speed detection signal

completion of acceleration/deceleration signal 

Designated frequency attainment signal

Failure signal (trip output)

Over-torque detection

Start/Stop

OL pre-alarm

Braking resistor overload pre-alarm

Over-torque detection pre-alarm

pre-alarm

Small-current detection

Significant failure

Insignificant failure

0/1

2/3

4/5

6/7

8/9

10/11

12/13

14/15

16/17

18/19

20/21

22/23

24/25

26/27

28/29

Function No.

Function

Ready for operation (including ST/RUN)

Ready for operation (excluding ST/RUN)

Frequency VIB selection

Fault signal (put out also at the time of a retry)

Specified data output 

Specified data output 2

Cumulative operation time alarm

Parts replacement alarm

Braking sequence output

F terminal input signal

Inversion of R terminal input signal

Signal in accordance of frequency command

Undervoltage detection

Invalid settings, always OFF (ignored)

Always OFF

Always ON

30/31

32/33

34/35

36/37

38/39

40/41

42/43

44/45

46/47

48/49

50/51

52/53

54/55

56-253

254

255

Note) For functions 0 to 55, even numbers are true logic and odd numbers are false logic. 

 Set parameters related to deep carrier frequency motor noise.

Carrier frequency parameters

Set characteristics if input frequency instruction is input from terminal block. 

Frequency command (terminal block) specialized parameters

Set protection operations, trip output and alarm output settings etc. 

Set specific values for functions such as low-speed/signal output and speed arrival signal output.

Input/output terminal function parameters 

A variety of functions can be given to various compatible output terminals by assigning the function
numbers for the parameter in the table below.  

Output terminal functions assignment parameters

Protection parameters 

Set to generate high torque to match load or motor.

Torque up parameters 

Set if changing units displayed or various display methods.

Panel display parameters

List of parameters

12  

DC Braking parameters

Title

Function

Adjustment range

Default setting

DC braking starting frequency

DC braking current

DC braking time

Motor shaft fixing control

0.0-       (Hz)

0-100 (%/A)

0.0-20.0 (s)

0: Invalid, 1: Valid (after DC braking)

0.0

50

1.0

0

Multi-stage speed run parameters

Power generation braking parameters

Jog run parameters

No. 2 and no. 3 acceleration/deceleration time setting parameters

No. 2 motor parameters

Jump frequency parameters

Forward/reverse/start frequency parameters

Analog/pulse train output setting parameters 

Communications functions parameters

Panel settings parameters

PID control setting parameters 

Others/option settings parameters

Title

Function

Adjustment range

Default setting

Droop gain

Droop insensitive torque band

Braking mode selection

Release frequency

Release time

Creeping frequency

Creeping time

Free notes

Parameter for option 1

Parameter for option 2

Parameter for option 3

Parameter for option 4

Parameter for option 5

Step-out detection current level

Step-out detection time

High-speed torque adjustment coefficient

0-100 (%)

0-100 (%)

0, 1, 2, 3

             -20.0 (Hz)

0.00-2.50 (s)

             -20.0 (Hz)

0.00-2.50 (s)

0-65535

0-65535

0-65535

0-65535

0-65535

0-65535

10-150 (%/A)

0.0: Invalid, 0.1-25.0 (s)

0.00-650.0

0

10

0

3.0

0.05

3.0

0.10

0

0

0

0

0

0

100

0.0

0.00

Parameters for setting higher functions.

Extended parameters

 

2

Detailed protection settings parameters

2005 Ver.112/113

 input terminal functions list 

Extended parameters

 

1

2005 Ver.112/113

Title

Function

Adjustment range

Always active function selection 1

Always-active function selection 2

Input terminal selection 1 (F)

Input terminal selection 2 (R)

Input terminal selection 3 (RES)

Input terminal selection 4 (S1)

Input terminal selection 5 (S2)

Input terminal selection 6 (S3)

Input terminal selection 7 (VIB)

Input terminal selection 8 (VIA)

0-75 (No function)

0-75 (ST)

0-75 (F)

0-75 (R)

0-75 (RES)

0-75 (SS1)

0-75 (SS2)

0-75 (SS3)

5-17 (SS4)

5-17 (AD2)

0

1

2

3

10

6

7

8

9

5

Default setting

A variety of functions can be given to various compatible input terminals by assigning the function numbers
for the parameter in the table below.  

Input terminal functions assignment parameters

Function

No.

Function

No.

Function

No function

Standby

Forward run command

Reverse run command

Jog run mode

Acceleration/deceleration 2 pattern selection

Preset-speed command 1

Preset-speed command 2

Preset-speed command 3

Preset-speed command 4

Reset command

Trip stop command from external input device

Switching of command mode and frequency setting mode

DC braking command

PID control prohibited

Permission of parameter editing

Combination of No. 1 and 10

Combination of No. 1 and 12

Combination of No. 2 and 4

Combination of No. 3 and 4

Combination of No. 2 and 5

Combination of No. 3 and 5

Combination of No. 2 and 6

Combination of No. 3 and 6

Combination of No. 2 and 7

Combination of No. 3 and 7

Combination of No. 2 and 8

Combination of No. 3 and 8

Combination of No. 2 and 9

Combination of No. 3 and 9

Combination of No. 2, 5 and 6

Combination of No. 3, 5 and 6

Combination of No. 2, 5 and 7

Combination of No. 3, 5 and 7

Combination of No. 2, 5 and 8

Combination of No. 3, 5 and 8

Combination of No. 2, 5 and 9

Combination of No. 3, 5 and 9

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

Function

Frequency command forced switching

No.2 Switching of V/F setting

Combination of No. 5, 39 and 61

Frequency UP signal input from external contacts

Frequency DOWN signal input from external contacts

Frequency UP/DOWN cancellation signal input from external contacts

Combination of No. 10 and 43

Inversion of No. 11

Thermal trip stop signal input from external device

Inversion of No. 46

Forced switching from remote to local control

Operation holding (stop of 3-wire operation)

Forced switching of command mode and terminal board command

Display cancellation of the cumulative power amount (kWh)

Forced operation (factory configuration required)

Fire-speed control

Coast stop (gate off)

Inversion of No. 10

Combination of No. 1 and 2

Combination of No. 1 and 3

Acceleration/deceleration 3 selection

Combination of No. 2 and 58

Combination of No. 3 and 58

Forced switching of stall prevention level 2

Holding of RY-RC terminal output

Holding of OUT-NO terminal output

Cancellation (clearing) of operation command from panel

PID control integral value clear

Combination of No. 1, 2 and 6

Combination of No. 1, 3 and 6

Combination of No. 1, 2 and 7

Combination of No. 1, 3 and 7

Combination of No. 1, 2 and 8

Combination of No. 1, 3 and 8

Combination of No. 1, 2 and 9

Combination of No. 1, 3 and 9

Combination of No. 1, 2 and 4

Combination of No. 1, 3 and 4

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

Output terminal selection 1A (RY-RC)

Output terminal selection 2A (OUT-NO)

Output terminal selection 3 (FL)

Output terminal selection 1B (RY-RC)

Output terminal selection 2B (OUT-NO)

Output terminal logic selection (RY-RC, OUT-NO)

0-255 (LOW)

0-255 (RCH)

0-255 (FL)

0-255 (always ON)

0-255 (always ON)

0, 1, 2, 3

4

6

10

255

255

0

Title

Function

Adjustment range

Default setting

Title

Function

Adjustment range

PWM carrier frequency

Random mode

Carrier frequency control mode selection

2.0-16.0 (kHz)

0: Invalid, 1: Automatic setting

0, 1, 2, 3

12.0

0

1

Default setting

Title

Function

Adjustment range

Frequency priority selection

VIA input point 1 setting

VIA input point 1 frequency

VIA input point 2 setting

VIA input point 2 frequency

Frequency setting mode selection 2

VIB input point 1 setting

VIB input point 1 frequency

VIB input point 2 setting

VIB input point 2 frequency

VIA input bias

VIA input gain

VIB input bias

VIB input gain

   

0

1

0

-

100 (%)

0

-

500 (Hz)

0

-

100 (%)

0

-

500 (Hz)

0

-

6 (same as                 )

0

-

100 (%)

0

-

500 (Hz)

0

-

100 (%)

0

-

500 (Hz)

-

0

0

0.0

100

50 (WP)

60 (WN)

1

0

0.0

100

50 (WP)

60 (WN)

-

Default setting

Title

Function

Adjustment range

Default setting

Low-speed signal output frequency

Speed reach setting frequency

Speed reach detection band

Analog/logic input function selection

(VIA/VIB terminal)

Frequency command agreement

detection range

0.0

0.0

2.5

0

2.5

0

-

        (Hz)

0

-

        (Hz)

0

-

        (Hz)

0

-

4

0

-

        (Hz)

Title

Function

Adjustment range

Default setting

Auto-restart control selection

Regenerative power ride-through control (Deceleration stop)

Retry selection (number of times)

Overvoltage limit operation (Slowdown stop mode selection)

Supply voltage correction (limitation of output voltage)

Stall prevention level 1

Inverter trip retention selection

Emergency stop selection

Emergency DC braking time

Output phase failure detection mode selection

Motor 150%-overload time limit

Input phase failure detection mode selection

0

0

0

2

3

150

0

0

1.0

0

300

1

0, 1, 2, 3, 4

0,1, 2

0: Invalid, 1-10 (times)

0, 1, 2, 3 

0, 1, 2, 3

10-199 (%/A), 200 (Invalid) 

   

0, 1

0, 1, 2 

0

-

20 (s)

0, 1, 2, 3, 4, 5

10-2400 (s)

0: Invalid, 1: Valid

Title

Function

Adjustment range

Auto-tuning

Slip frequency gain

Automatic torque boost value

Motor rated current

Motor no-load current

Motor rated speed

Speed control response coefficient

Speed control stability coefficient

0

50

* 1

* 1

* 1

1710

40

20

0, 1, 2

0-150 (%)

0-30 (%)

0.1-100.0 (A)

10-90 (%)

100-32000 (min-1)

1-150

1-100

Default setting

* 1: Default values vary depending on the capacity.

Title

Function

Adjustment range

Default setting

Unit selection

Free unit selection

Inclination characteristic

of free unit display

Free unit display bias

Free step 1 (pressing a panel key once)

Free step 2 (panel display)

Standard monitor display selection

Canceling of operation command

when standby terminal (ST) is turned off

Panel stop pattern

0

0.00

1

0.00

0.00

0

0

1

0

0: %, 1: A (ampere)/V (volt)

0.00: Invalid, 0.01-200.0

0: Negative inclination, 

1: Positive inclination

0-        (Hz)

0.00: Invalid, 0.01-        (Hz)

0: Invalid, 1-255

0,1,2,3,4,5,6,7 

0: Operation command canceled (cleared),

1: Operation command retained

0: Slowdown stop, 1: Coast stop

      

Summary of Contents for TOSVERT VF-S11

Page 1: ...ns must be studied carefully When using our inverters for critical equipment even though the inverters are manufactured under strict quality control always fit your equipment with safety devices to prevent serious accident or loss should the inverter fail such as issuing an inverter failure signal Do not use our inverters for any load other than three phase induction motors None of Toshiba its sub...

Page 2: ...ditioning systems and plant line control systems As well as being highly expandable the VF S11 uses a detachable type of control terminal board which allows you to easily mount optionally available communication boards RS 485 DeviceNet and LonWorks DeviceNet is a registered trademarks of ODVA Open DeviceNet Vendor Association For users who need a wide capacity and range of models For obtaining spa...

Page 3: ...omentary monitor values for when a trip occurs can be viewed Ten monitor values are stored in memory for the last four inverter operations which is effective in pin pointing the cause of a trip Storage of user parameter settings All parameter settings made by the user can be stored in memory Stored parameters can be immediately called even they have been changed History function This function is f...

Page 4: ...the range of 50 to 600V by correcting the supply voltage not adjustable above the input voltage 0 5 to 500 0Hz default setting 0 5 to 80Hz maximum frequency 30 to 500Hz 0 01Hz operation panel setting 0 1Hz analog input when the max frequency is 100Hz V f constant variable torque automatic torque boost vector control automatic energy saving dynamic automatic energy saving control Auto tuning Base f...

Page 5: ...g across F CC causes forward rotation open causes slowdown and stop Shorting across R CC causes reverce rotation open causes slowdown and stop RES S1 S2 S3 Shorting across S1 CC causes preset speed operation Shorting across S2 CC causes preset speed operation Shorting across S3 CC causes preset speed operation CC PLC Control circuit s equipotential terminal sink logic 3 common terminals for input ...

Page 6: ... 5 5 0 5 1 9 6 9 6 1 0 1 0 1 2 1 4 2 2 1 3 1 3 2 1 2 2 4 7 4 7 8 8 8 8 3 phase 240V 3 phase 500V Input voltage Applicable motor kW Type H W D H1 H2 Approx weight kg W1 D2 Drawing Dimensions mm 0 4 0 55 0 75 1 5 2 2 4 0 5 5 7 5 11 15 0 4 0 75 1 5 2 2 4 0 5 5 7 5 11 15 0 2 0 4 0 75 1 5 2 2 0 75 1 5 2 2 4 0 5 5 7 5 11 15 VFS11 2004PM VFS11 2005PM VFS11 2007PM VFS11 2015PM VFS11 2022PM VFS11 2037PM VF...

Page 7: ...rs Protection parameters Set to generate high torque to match load or motor Torque up parameters Set if changing units displayed or various display methods Panel display parameters List of parameters 12 DC Braking parameters Title Function Adjustment range Default setting DC braking starting frequency DC braking current DC braking time Motor shaft fixing control 0 0 Hz 0 100 A 0 0 20 0 s 0 Invalid...

Page 8: ...put and output cables etc of the inverter To prevent current leakage it is recommended to take the following measures Effects of leakage current Leakage current which increases when an inverter is used may pass through the following routes Route 1 Leakage due to the capacitance between the ground and the noise filter Route 2 Leakage due to the capacitance between the ground and the inverter Route ...

Page 9: ...CL High attenuation radio noise filter NF type Braking resistor Conduit pipe attachment kit Motor end surge voltage suppression filter for 500V class only Zero phase reactor ferrite core type EMC noise filter Compliant with European standards P 17 P 18 P 18 P 9 P 20 P 20 P 19 P 18 P 19 P 19 P 19 P 20 Used to improve the input power factor reduce the harmonics and suppress external surge on the inv...

Page 10: ...ox with cover 4 ØF holes AC reactor Power source AC reactor Power source P Earth terminal Power source LC filter Model Rated current A Inverter type Diagram Terminals Approx weight kg Dimensions mm W H D X Y d1 d2 DCLS 2002 DCL 2007 DCL 2022 DCL 2037 DCL 2055 DCL 2110 DCL 2220 DCL 2007 DCL 2022 DCL 4110 DCL 4220 2 5 7 14 22 5 38 75 150 7 14 38 75 79 92 86 86 75 100 117 92 86 95 105 50 65 110 110 1...

Page 11: ...devices 19 Devices External dimensions and connections Motor end surge voltage suppression filter for 500V class only Parameter writer Extension panel Motor end surge voltage suppression filter l Invertor type Approx weight kg MSF 4015Z MSF 4037Z MSF 4075Z MSF 4150Z Dimensions mm Depth 12 20 30 40 Terminal screw M4 M4 M5 M5 Grounding screw M4 M4 M5 M5 VFS11 4004 4015PL VFS11 4022 4037PL VFS11 4055...

Page 12: ...it breaker Minimum wiring Cooling structure Self cooling type 22 21 Command mode selection Frequency setting mode selection 1 0 Function VF S11 Standard type 0 2 VF S11 otally enclosed type Title External dimensions Fig F 3ph 240V 3ph 500V 1ph 240V VFS11 2004PME VFS11 2007PME VFS11 2015PME VFS11 2022PME VFS11 2037PME VFS11 4007PLE VFS11 4015PLE VFS11 4022PLE VFS11 4037PLE VFS11 4055PLU VFS11 4075P...

Reviews: