background image

AB

Printed in Japan

05-08 (AB)8692A

To users of our inverters : 

Our inverters are designed to control the speeds of three-phase induction motors for general industry.

For further information, please contact your nearest Toshiba Representative or International Operations-Producer Goods.

The information in this brochure is subject to change without notice. 

In Touch with Tomorrow

Overseas Sales & Marketing Department 
Electrical Apparatus & Measurement Division 

1-1,Shibaura 1-chome, Minato-ku, 
Tokyo 105-8001,Japan 
Tel.: +81(0)3-3457-4911  Fax.: +81(0)3-5444-9268

TOSHIBA CORPORATION 

INDUSTRIAL AND POWER SYSTEMS & SERVICES COMPANY

* Read the instruction manual before installing or operating the inverter unit and store it in a safe place for reference.
* When using our inverters for equipment such as nuclear power control, aviation and space flight control, traffic, and safety, and there 

is a risk that any failure or malfunction of the inverter could directly endanger human life or cause injury, please contact our 
headquarters, branch, or office printed on the front and back covers of this catalogue. Special precautions must be taken and such 
applications must be studied carefully.  

* When using our inverters for critical equipment, even though the inverters are manufactured under strict quality control always fit 

your equipment with safety devices to prevent serious accident or loss should the inverter fail (such as issuing an inverter failure  
signal). 

* Do not use our inverters for any load other than three-phase induction motors.
* None of Toshiba, its subsidiaries, affiliates or agents, shall be liable for any physical damages, including, without limitation, 

malfunction, anomaly, breakdown or any other problem that may occur to any apparatus in which the Toshiba inverter is incorporated 
or to any equipment that is used in combination with the Toshiba inverter. Nor shall Toshiba, its subsidiaries, affiliates or agents be 
liable for any compensatory damages resulting from such utilization, including compensation for special, indirect, incidental, 
consequential, punitive or exemplary damages, or for loss of profit, income or data, even if the user has been advised or apprised of 
the likelihood of the occurrence of such loss or damages.

Precautions

! 

Transistor Inverter

1-phase 240V 0.2kW to 2.2kW 
3-phase 240V 0.4kW to 15kW 
3-phase 500V 0.4kW to 15kW 
3-phase 600V 0.75kW to 15kW

New Global Standard Inverter 

TOSVERT 

TM

Built-in EMI noise filter

Introducing the world’s top class compact inverter

Summary of Contents for TOSVERT VF-S11

Page 1: ...ns must be studied carefully When using our inverters for critical equipment even though the inverters are manufactured under strict quality control always fit your equipment with safety devices to prevent serious accident or loss should the inverter fail such as issuing an inverter failure signal Do not use our inverters for any load other than three phase induction motors None of Toshiba its sub...

Page 2: ...ditioning systems and plant line control systems As well as being highly expandable the VF S11 uses a detachable type of control terminal board which allows you to easily mount optionally available communication boards RS 485 DeviceNet and LonWorks DeviceNet is a registered trademarks of ODVA Open DeviceNet Vendor Association For users who need a wide capacity and range of models For obtaining spa...

Page 3: ...omentary monitor values for when a trip occurs can be viewed Ten monitor values are stored in memory for the last four inverter operations which is effective in pin pointing the cause of a trip Storage of user parameter settings All parameter settings made by the user can be stored in memory Stored parameters can be immediately called even they have been changed History function This function is f...

Page 4: ...the range of 50 to 600V by correcting the supply voltage not adjustable above the input voltage 0 5 to 500 0Hz default setting 0 5 to 80Hz maximum frequency 30 to 500Hz 0 01Hz operation panel setting 0 1Hz analog input when the max frequency is 100Hz V f constant variable torque automatic torque boost vector control automatic energy saving dynamic automatic energy saving control Auto tuning Base f...

Page 5: ...g across F CC causes forward rotation open causes slowdown and stop Shorting across R CC causes reverce rotation open causes slowdown and stop RES S1 S2 S3 Shorting across S1 CC causes preset speed operation Shorting across S2 CC causes preset speed operation Shorting across S3 CC causes preset speed operation CC PLC Control circuit s equipotential terminal sink logic 3 common terminals for input ...

Page 6: ... 5 5 0 5 1 9 6 9 6 1 0 1 0 1 2 1 4 2 2 1 3 1 3 2 1 2 2 4 7 4 7 8 8 8 8 3 phase 240V 3 phase 500V Input voltage Applicable motor kW Type H W D H1 H2 Approx weight kg W1 D2 Drawing Dimensions mm 0 4 0 55 0 75 1 5 2 2 4 0 5 5 7 5 11 15 0 4 0 75 1 5 2 2 4 0 5 5 7 5 11 15 0 2 0 4 0 75 1 5 2 2 0 75 1 5 2 2 4 0 5 5 7 5 11 15 VFS11 2004PM VFS11 2005PM VFS11 2007PM VFS11 2015PM VFS11 2022PM VFS11 2037PM VF...

Page 7: ...rs Protection parameters Set to generate high torque to match load or motor Torque up parameters Set if changing units displayed or various display methods Panel display parameters List of parameters 12 DC Braking parameters Title Function Adjustment range Default setting DC braking starting frequency DC braking current DC braking time Motor shaft fixing control 0 0 Hz 0 100 A 0 0 20 0 s 0 Invalid...

Page 8: ...put and output cables etc of the inverter To prevent current leakage it is recommended to take the following measures Effects of leakage current Leakage current which increases when an inverter is used may pass through the following routes Route 1 Leakage due to the capacitance between the ground and the noise filter Route 2 Leakage due to the capacitance between the ground and the inverter Route ...

Page 9: ...CL High attenuation radio noise filter NF type Braking resistor Conduit pipe attachment kit Motor end surge voltage suppression filter for 500V class only Zero phase reactor ferrite core type EMC noise filter Compliant with European standards P 17 P 18 P 18 P 9 P 20 P 20 P 19 P 18 P 19 P 19 P 19 P 20 Used to improve the input power factor reduce the harmonics and suppress external surge on the inv...

Page 10: ...ox with cover 4 ØF holes AC reactor Power source AC reactor Power source P Earth terminal Power source LC filter Model Rated current A Inverter type Diagram Terminals Approx weight kg Dimensions mm W H D X Y d1 d2 DCLS 2002 DCL 2007 DCL 2022 DCL 2037 DCL 2055 DCL 2110 DCL 2220 DCL 2007 DCL 2022 DCL 4110 DCL 4220 2 5 7 14 22 5 38 75 150 7 14 38 75 79 92 86 86 75 100 117 92 86 95 105 50 65 110 110 1...

Page 11: ...devices 19 Devices External dimensions and connections Motor end surge voltage suppression filter for 500V class only Parameter writer Extension panel Motor end surge voltage suppression filter l Invertor type Approx weight kg MSF 4015Z MSF 4037Z MSF 4075Z MSF 4150Z Dimensions mm Depth 12 20 30 40 Terminal screw M4 M4 M5 M5 Grounding screw M4 M4 M5 M5 VFS11 4004 4015PL VFS11 4022 4037PL VFS11 4055...

Page 12: ...it breaker Minimum wiring Cooling structure Self cooling type 22 21 Command mode selection Frequency setting mode selection 1 0 Function VF S11 Standard type 0 2 VF S11 otally enclosed type Title External dimensions Fig F 3ph 240V 3ph 500V 1ph 240V VFS11 2004PME VFS11 2007PME VFS11 2015PME VFS11 2022PME VFS11 2037PME VFS11 4007PLE VFS11 4015PLE VFS11 4022PLE VFS11 4037PLE VFS11 4055PLU VFS11 4075P...

Reviews: