![Toshiba TheaterWide 23HL85 Service Manual Download Page 8](http://html.mh-extra.com/html/toshiba/theaterwide-23hl85/theaterwide-23hl85_service-manual_1138278008.webp)
- 8 -
2. Adjustment
Note: In this "Adjustment" section, [ ] shows a button.
2-1.Adjustment Tools and Conditions
Tools:
Pattern Generator (801GF, MSPG925F)
DDC Adjustment Tool
PC
Remote
Control
Conditions: Heat Run 30 minutes or more
2-2. Auto Gain/Offset Adjustment
2-2-1. RF Mode Adjustment (normal TV receive mode)
No reguired
2-2-2. Component Mode Adjustment
Preparation
Carry out Heat Run for 30 minutes or more before adjustment
(with no RF signal).
1) Connect Y, Pb, and Pr output signals of Pattern Generator
to the component jack (Y, Pb, Pr) of LCD TV.
2) Connect Y, Pb, and Pr output signals of Pattern Generator
to the component jack (D Jack) of LCD TV.
3) Change the TV input mode to component mode.
4) Select 480p Mode (Y:100% Pb/Pr:75%) in Pattern Generator. Select Pattern 33 (Color Bar Pattern
signal) in Pattern Generator (MSPG925F).
5) Go into service mode, and Auto Gain menu appears, and then press VOL [+].
6) Press [OK] to store the adjustment data.
2-2-3. PC Mode Adjustment
Preparation
Carry out Heat Run for 30 minutes or more before adjustment (with no RF signal).
Connect Pattern Generator to the 15-pin D-Sub Jack of LCD TV.
1) Change the TV input mode to PC mode.
2) Set Pattern Generator to the following:
XGA (1024x768) 16-step or 11-step grayscale
3) Go into service mode, and Auto Gain menu appears, and then press VOL [+].
4) Press [ENTER] to store the adjustment data.
(Adjustment in component mode or PC mode)