2
‒
CODE No. (DN) setting
■
Wired remote controller (RBC-AMS5 E-UL)
Perform the advanced settings for the air conditioner. Carry out the setting operation
while the indoor unit is stopped. (Turn off the air conditioning unit before starting the
setting operation.)
6.Setting timer operation mode
Field setting menu(2/2)
Return
Set
7.DN setting
8.Reset power consumption data
6. Setting timer operation mode
7. DN setting
8. Reset power consumption data
Field setting menu(2/2)
Return
Set
Display example of
AMS5 E-UL
1. Push the [
MENU] button to display the menu screen.
2. Push and hold the [
MENU] button and the [
ޕ
] button at the same time
to display the “Field setting menu”.
Push and hold the buttons for more than 4 seconds.
DN setting
Code
(DN)
Data
Return
B5
0000
Fix
<
>
DN setting
Code
(DN)
Data
Return
B5
0001
Fix
<
>
3. Push the [
ޔ
] / [
ޕ
] button to select “7. DN setting” on the
“Field setting menu” screen, then push the “
Set
Set” [
F2] button.
The fan and louver of the indoor unit operate. When the group control is used, the
fan and louver of the selected indoor unit operate.
Move the cursor to select “DN code” with the “
<
<
” [ F1] button, then
set “B5” with the [
ޔ
] / [
ޕ
] button.
Move the cursor to select “data” with the “
>
>
” [ F2] button, then set
“0001” with the [
ޔ
] / [
ޕ
] button.
Return
Continue?
No
Yes
DN setting
4. Push the [
MENU] button to set the other DN codes. After “Continue?” is
displayed on the screen.
5. Push the “
No
No” [
F2] button to
fi
nish the setting operation.
“ ” appears on the screen for a while, then the screen returns to the “Field setting
menu” screen.
Pushing the “
No
No” [ F2] button displays the unit selection screen
when the group control is used. Push the [
CANCEL] button on the unit
selection screen to
fi
nish the setting operation. “ ” appears on the screen for a
while, then the screen returns to the “Field setting menu” screen.
6. Push the [
CANCEL] button to return.
About the occupancy sensor
• Sometimes the sensor may not detect people even when they are present if their
movements are small.
• If something having a difference in temperature with the surroundings moves, the
sensor may detect people as present even if they are not present.
• A wired remote controller (RBC-AMS5 E-UL) is required to use an occupancy
sensor.
• Be sure to install an occupancy sensor in all indoor units if using group operation.
List of separately available products that cannot be used with
the occupancy sensor
The following separately available products cannot be used together with the
Occupancy sensor.
Product name
Model
Wireless receiver kit
RBC-AX33UYP-UL
Air puri
fi
er kit
TCB-EAPC1UYHP-UL