– 2 –
2-EN
How to install the Air puri
fi
er
Install Air purifier to indoor unit
1
•
Match the direction of triangle mark between Air puri
fi
er and drain-pan 3 places
before insert slot hole.
•
Insert slot hole of Air puri
fi
er to pin on the drain-pan of indoor unit 3 place
on the direction of arrow
1
.
1
Drain-pan
Pin
2
•
Push the Air puri
fi
er to
fi
tting with upper cabinet of indoor unit on the direction
of arrow
2
.
2
Cabinet upper
Air puri
fi
er
•
Fix steel screw Ø4 x 8L two places.
Screw
3
Remove protection sheet by pull out follow arrow direction.
4
Fix earth screw Ø4 x 10L for
fi
xed earth cable with upper cabinet.
Earth screw
Earth lead
Washer
Wiring and connecting cable
•
Stick wire clamp to upper cabinet by release adhesive paper position nearly
electrical box.
•
Wiring the connecting cable through to the clamp.
Stick wire clamp on this area
Electrical box
Wire clamp
How to install the Dust sensor
1.
Assembly Dust sensor to ceiling panel.
•
Connect Dust sensor cable to Dust senser module.
Dust sensor module
Dust sensor cable
•
Insert Dust sensor module to ceiling panel in the direction of arrow and push
to
fi
tting with hook of ceiling panel.
Dust sensor
Ceiling panel hook
Ceiling panel
“Click”
“Click” sound is occured when Dust sensor
complete insertion
2.
Wiring the Dust sensor cable through to the clamp in the back side
of the ceiling panel.
Dust sensor cable
Dust sensor
Wire clamp
How to install the Option P.C. board
1.
Assembly Option P.C. board to electrical box.
•
Insert the Spacer to square hole of electrical box 4 pcs.
•
Push Option P.C. board to Spacer pin 4 place.
Option P.C. board
Spacer