background image

Toshiba America Information Systems Inc. ("TAIS") shall not be liable for damages of any kind for use of this information, which is subject to
change without notice.     Copyright 1994 TAIS.     3200sx.doc  Rev. 2   04/04/00  MQC/nmm.

Page 2

T3200SX 

(continued)

IBM PC/XT Compatible Expansion Slots

1 full length IBM PC/XT/286 compatible low profile 16 bit ISA slot;
1 half length IBM PC/XT compatible low profile 8-bit ISA slot

Maximum card sizes:
16-bit long slot

333./- .5mm x 106.68mmW
99.06mmW +/- .3mm w/o connector
33mmH or 13mmH if short slot used

8-bit short slot

140mmL x 13mmH, width same as 16 bit

Hardware Switches and Controls
1) Power on/off

Located on back of computer

2) A/B/PRT switch

Located on right side of computer
With switch set to "A", external FDD port is accessed as drive A; internal 3.5" FDD as drive B.
With switch set to "B", external FDD port is accessed as drive B, internal 3.5" FDD as drive A.
Switch is set to "PRT" for parallel printer output.
Computer must be re-booted for switch change to take effect.

3) Plasma display brightness dial

Located on right side of display

Environmental Specifications
1) Operating condition

Ambient temperature:

41 to 95 degrees F.     5 to 35 degrees C.

Relative Humidity:

20% to 80% non-condensing

2) Non-Operating condition

Ambient temperature:

-4 to 140 degrees F.     -20 to 60 degrees C.

Relative Humidity:

5% to 90% non-condensing

 

T3200SX 

(continued)

Summary of Contents for T-Series T3200sx

Page 1: ...drive One 40MB or one 120MB hard disk drive Operating system included Toshiba MS DOS 3 30 or 4 01 Software Compatibility Compatible with software written for the IBM PC XT AT using VGA EGA CGA or T3100 AT T 6300 640 x 400 high resolution graphics mode Interfaces VGA color video port Built in dedicated modem slot D form factor 2 RS 232 C serial ports Parallel printer external diskette or tape drive...

Page 2: ... bit Hardware Switches and Controls 1 Power on off Located on back of computer 2 A B PRT switch Located on right side of computer With switch set to A external FDD port is accessed as drive A internal 3 5 FDD as drive B With switch set to B external FDD port is accessed as drive B internal 3 5 FDD as drive A Switch is set to PRT for parallel printer output Computer must be re booted for switch cha...

Page 3: ...nger manufactured PC PA7310U Expansion chassis requires expansion chassis interface card no longer manufactured PC PA7313E Expansion interface card no longer manufactured PC PA5467U ToshibaLAN 16 bit Ethernet Card Toshiba proprietary slot no longer manufactured PC PA5466U ToshibaLAN 8 bit Ethernet card IBM AT compatible 1 2 card 8 bit no longer manufactured PC PA722L TD80 external tape drive no lo...

Page 4: ...hiba modem or others 13 Math coprocessor 14 Hard disk 15 Reserved I O Port Assignment Port Address From To Device Function___________ 000 01F 82C37A DMA Controller 1 020 03F 82C59A Interrupt Controller 1 040 05F 82C54 Timer 060 06F 8742 Keyboard Controller 070 07F RTC NMI 080 09F DMA Page Register 0A0 0BF 82C59A PIC 2 0C0 0DF 82C37A DMA Controller 2 0E0 0FF NDP Error Clear Port 100 1EF Not Used 1F...

Reviews: