background image

Stratagy iES32 Installation Guide

Installing Stratagy iES32 in Network with Static IP Address

Stratagy iES32 Installation Guide    06/02

11

You must also add a notification application to Mailbox 999 so that you are notified when the 
temperature reaches the warning threshold.

To add the warning notification to mailbox 999

1. Select UserAgents > Edit User Agents > Mailbox.

2. Select User ID 999 at the bottom of the screen. Mailbox 999 displays on the screen.

3. Select the Notify tab. The Notify screen displays.

4. Click Add. A dialog box displays on the screen.

5. From the Event field drop-down menu, select “temperature > warning threshold”.

6. Complete the Title field and click OK. The notify record is added to the record summary 

section of the screen.

7. Modify the fields on the screen as appropriate.

8. Click Apply. The notify record is saved.

For additional information on adding notifications, see Chapter 6 – Messaging Voice Processing 
(MVP) in the Stratagy ES Installation and Maintenance Manual.

Installing Stratagy iES32 in Network with Static IP 

Address

1. In Strata CTX Program 100 Card Assignment, set cabinet slot PCB type for the Stratagy iES32 

to BDKU/BDKS without OCA.

2. In Strata CTX Program 204 Station Assignment DKT, the station’s parameters for Stratagy 

iES32 should be set to:

FK5 Tone First

FK19 Not Continuous

FK21 BPCI.

3. Bring up Netmeeting on the Admin PC by clicking Programs > Accessories > Communications 

> Netmeeting.

4. In the Netmeeting program, click Tools > Options > Security.

5. Under Outgoing Calls, select “I prefer to make secure outgoing calls.”

6. Under Certificate, select “Use privacy (Encryption) only” then click OK. 

7. Click the phone Icon. It brings up the Place a Call box. 

8. In the To field, type iES32’s IP Address (192.168.254.252 is the default). That brings up a box 

called Remote Desktop Sharing Password, User Name “Administrator” Password 
“Administrator” leave Domain blank. This completes the connection between iES32 and the 
Admin PC using NetMeeting.

9. To start Stratagy ES Admin on the Admin PC, from Windows NT click on Start > Program > 

Stratagy ES Administration > Stratagy ES Administration. The Stratagy Login screen displays.

10. In the Computer field, type the IP address of the Stratagy iES32. Press 

Tab

.

11. In the Name field, type Stratagy. Press 

Tab

.

12. In the Password field, type Stratagy. Click OK.

Summary of Contents for Stratagy iES32

Page 1: ...Installation Guide Stratagy iES32 Enterprise Server STRATAGY IMPORTANT Installing Technician Please Read This guide contains the essential information for the proper installation of Stratagy ES hardware ...

Page 2: ...s as engineering or manufacturing methods may warrant SES IG IES32 VA 4025095 Version A June 2002 Copyright 2002 Toshiba America Information Systems Inc Telecommunication Systems Division All rights reserved No part of this manual covered by the copyrights hereon may be reproduced in any form or by any means graphic electronic or mechanical including recording taping photocopying or information re...

Page 3: ...Y OF NON INFRINGEMENT OF THIRD PARTY RIGHTS THE WARRANTY OF YEAR 2000 COMPLIANCE AND THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE SOFTWARE IS WITH YOU NEITHER TAIS NOR ITS SUPPLIERS WARRANT THAT THE FUNCTIONS CONTAINED IN THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT THE OPERATION OF THE SOFTWARE WILL BE ...

Page 4: ...ch defective or missing parts as are causing the malfunction with new or refurbished parts at their option If TAIS or one of its authorized dealers does not replace or repair such parts the retail customer s sole remedy will be a refund of the price charged by TAIS to its dealers for such parts as are proven to be defective and which are returned to TAIS through one of its authorized dealers withi...

Page 5: ...ent Retain the packing materials for re use when transporting system hardware CAUTION You will be handling iES32 when it is most fragile unpacked and exposed The iES32 if handled properly will give long reliable service To ensure that the unit is not damaged during installation or maintenance follow these precautions Damage may not always be immediately evident e g no physical damage on the outsid...

Page 6: ...il Hunt Group This value should be the same as Number to Display in Program 209 see Substep 7 below Program 204 Change station s parameters to Tone First Adapter BPCI Set Continuous DTMF to Not Continuous Copy the changes to all voice mail stations 2 Install and program serial card BSIS in the Strata CTX Note TPI is required for iES32 A BSIS card must be installed in the Strata CTX 3 Install a ser...

Page 7: ...ere are four slots S101 S104 in the base cabinet and four slots S105 S108 in the expansion cabinet available for use by iES32 The following figure and table gives you the information on the number of ports available for installation in each slot If more than 16 ports are to be used in slots S101 S105 or S107 then the corresponding slot S102 S106 or S108 respectively must be left empty CTX100 Cabin...

Page 8: ... information delivered to that slot for the second group of ports To help protect against Strata CTX configuration errors the physical profile of iES32 extends into the adjacent CTX card slot when configured with the second daughterboard See figure and table below CTX670 Base Cabinet Slots B101 B102 S101 S102 S103 S104 S105 S106 S107 S108 BECU BBCU 16 ports 16 ports 16 ports 16 ports 16 ports 16 p...

Page 9: ... into the adjacent CTX card slot when configured with the second daughterboard The next two slots slots S_07 S_08 in the cabinet can only accommodate a iES32 with eight ports Slots S_09 and S_10 cannot be used CTX670 Expansion Cabinet Slots S_01 S_02 S_03 S_04 S_05 S_06 S_07 S_08 S_09 S_10 16 ports 16 ports 16 ports 16 ports 16 ports 16 ports 8 ports 8 ports 32 ports Empty 32 ports Empty 32 ports ...

Page 10: ...separate Windows 2000 ME 98 or Windows NT computer using Stratagy ES Administration software The Network port can be connected in one of two ways The one you use depends upon the features enabled in iES32 e g UM the network requirements of the Strata CTX and the end users network environment When using UM a straight through network cable used with a network hub is required This is because of the n...

Page 11: ...d RJ45 8 pin jack TD TD Not Used RD RD Not Used Not Used Not Used 2 1 4 3 6 5 8 7 CTX Network Interface Jack P7 TIA Network Wall Jack Wire Color Codes CAUTION Do not mix different TIA Wall Jack Types in an Installation Pair 2 Pair 3 Pin 1 Pin 2 Pin 3 Pin 6 Green Green White Orange White Orange TIA 568A White Green Green White Orange White White Orange TIA 568B Network Interface Jack Pin Numbers 60...

Page 12: ...RJ11 type connector RJ25C The six conductor phone cable enables a direct connection between the serial port outputs of the Strata CTX and iES32 Step 7 Restart Strata CTX and Verify Stratagy iES32 is Functioning Properly Note Each iES32 has been preprogrammed at the factory for out of box operation on the Strata CTX This includes the integration and configuration parameters and company greeting and...

Page 13: ...h a LAN Wide Area Network WAN To install Stratagy Administration Software 1 Insert the CD ROM Disk into the PC drive The Software Menu displays 2 Select Stratagy ES Administration The Welcome screen displays 3 Accept the defaults on the following screens by clicking Next 4 When the installation is complete click Finish 5 Restart the Stratagy ES Server 6 Remove the CD ROM from the drive Step 10 Con...

Page 14: ...must be recorded at these thresholds for three consecutive checks before notification or shutdown occurs Current temperatures can be checked through Trace or NT Event Viewer Note Event viewer only shows temperature at time of system start up or if there is a reading outside of the specified range CAUTION Adjustment to any of these parameters could cause iES32 to not shut down at the appropriate te...

Page 15: ...n Strata CTX Program 100 Card Assignment set cabinet slot PCB type for the Stratagy iES32 to BDKU BDKS without OCA 2 In Strata CTX Program 204 Station Assignment DKT the station s parameters for Stratagy iES32 should be set to FK5 Tone First FK19 Not Continuous FK21 BPCI 3 Bring up Netmeeting on the Admin PC by clicking Programs Accessories Communications Netmeeting 4 In the Netmeeting program cli...

Page 16: ...ecom toshiba com 2002 Toshiba America Information Systems Inc Printed in U S A Stratagy is a registered trademark of Toshiba America Information Systems Inc Strata is a registered trademark of Toshiba Corporation Specifications subject to change without notice Some features require optional hardware to support full capabilities ...

Reviews: