background image

June 2006

TOSHIBA                              

Business Communications Division

Strata CIX IPT/DKT Telephone

         

Administrator Manual

Summary of Contents for STRATA CIX DKT

Page 1: ...June 2006 TOSHIBA Business Communications Division Strata CIX IPT DKT Telephone Administrator Manual ...

Page 2: ...wever all liability for errors or omissions is excluded CIX AG DKIPT VA Version A 1 June 2006 Copyright 2006 Toshiba Information Systems UK Ltd Business Communications Division All rights reserved No part of this manual covered by the copyrights hereon may be reproduced in any form or by any means graphic electronic or mechanical including recording taping photocopying or information retrieval sys...

Page 3: ...may not be treated as household waste By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about the take back and recycling of this product please contact your supplier where you purchased the product ...

Page 4: ...m and hereby exclude all conditions warranties and other terms with regard to the Software including but not limited to any conditions warranties and other terms of non infringement of third party rights year 2000 compliance merchantability satisfactory quality and fitness for a particular purpose relating to the ownership of the Software or as to price in every case whether express or implied by ...

Page 5: ...hone Programming Mode 10 Telephone Program Option Reset 10 Dial Pad and Button Beeps 11 Speakerphone Microphone Sensitivity Adjustment 11 Call Waiting and Camp on Ring Tone Over Handset Headset Option 12 Reset and Adjust the LCD Contrast 12 Changing the Functions of the Flex and Msg Buttons 14 Redial Feature Button Activation Deactivation 14 Msg Feature Button Activation Deactivation 14 Headset Tr...

Page 6: ...nction Settings 19 Setting the IP Telephone Headset Transmit Volume 20 Viewing IP Telephone Terminal Information 20 Chapter 3 IPT2008 SDL Settings Configurations 21 Loop Back Test 22 Network Settings 25 Advanced Network Settings 31 Sound Settings 37 Key Repeat 40 Other Setting 42 Initialise 44 Reset 47 Factory 47 Notes to Users 51 Index 61 ...

Page 7: ...3200 3500 series digital telephones Strata Digital Add on Module DADM Strata IP Add on Module IADM2020 Strata Direct Station Selection DSS console Organisation Chapter 1 Administrator Mode Chapter 2 DKT IPT Settings Chapter 3 IPT2008 SDL Settings How to Use This Guide This guide provides in depth instructions for the IPT2000 series DKT3000 3200 3500 series telephones and their features Most teleph...

Page 8: ...4 A station is considered busy when all extensions are being used Note The naming convention for DKT assignments within Toshiba is Directory Numbers For clarity and ease of understanding the terms Extension Number and Phantom Extension Number will be used in this document in lieu of PDN and PhDN Arial Bold Represents telephone buttons shows a multiple PC keyboard or telephone button entry Entries ...

Page 9: ...documents listed here may appear in different versions on the CD ROM or in print To find the most current version check the version date in the Publication Information on the back of the document s title page Refer to the following for more information Strata CIX IPT DKT Telephone User Guide Toshiba Partner Portal Website ...

Page 10: ...Introduction Related Documents Media vi Strata CIX Telephones Administrator Manual 6 06 ...

Page 11: ...ng by the telephone system administrator Functions Using the soft keys on your telephone you can program the following functions in Administrator mode Phone Name enter the Extension PDN name for any telephone in the Strata CIX Door Name enter door phone name System SD Name1 enables you to program system speed dial names Station SD Name1 enables you to program station speed dial names for any stati...

Page 12: ...quate to the second third and fourth soft keys on the IPT or Page Scroll and Feature on the DKT 7509 MY EXTR INTR SELECT DIRECTORY SK1 SK2 SK3 SK4 DIAL SK1 or Mode Previous Menu exit Admin mode SK2 or Page Previous Item screen Back or move cursor to Left column SK3 or Scroll Next Item screen Forward or move cursor to Right column Hold Enter Notes You can use SK2 or SK3 Page Scroll button to select...

Page 13: ... shown in Table 1 Table 1 Dial Pad Alphanumeric Characters Dial Pad Buttons Number of times to press the dial pad button 1 2 3 4 5 1 1 2 A B C 2 3 D E F 3 4 G H I 4 5 J K L 5 6 M N O 6 7 P Q R S 7 8 T U V 8 9 W X Y Z 9 0 0 Note When using the Alphanumeric dial pad use SK2 to Back Space and delete a character use SK3 to enter a space in a name ...

Page 14: ...eral Operation on page 2 to navigate between functions Press Hold Enter the DN ID number This is the extension number PDN of the telephone Enter the Phone Name that corresponds with that DN ID Press Hold pressing Hold will register the name and let you make the next Phone name entry Press SK1 to cancel or go back Note Once the name is registered you cannot cancel the entry Press SK2 to move to the...

Page 15: ...Press Hold to register alphanumeric name corresponding to the entered speed dial index Note To enter a speed dial number refer to Speed Dial in the Advanced section of this guide Press Hold Enter the DN ID This is the extension number PDN of the telephone Pressing SK1 lets you return to the previous screen and Hold registers the entry Enter the speed dial index 00 99 Enter the alphanumeric name Pr...

Page 16: ...anual 06 06 Press Hold Enter the ILG number 1 128 Pressing SK1 lets you return to the previous screen and Hold registers the entry Enter the DDI number Enter the alphanumeric name that corresponds to the DDI Number Press Hold to register the entry DNIS NAME ILG 003 ILG 003 DID ...

Page 17: ...formation before doing any of the steps found in this chapter IP address subnet mask number router address Station ID CIX Strata Net node number IP address for the LIPU etc Notes You may want to enter a period or backspace when performing the following steps While in telephone programming mode Press 3 6 9 Hold simultaneously to enter programming mode you can use these buttons for the following fun...

Page 18: ...re Buttons FB The following illustrations show you the location of these FB buttons on 20 10 and 14 button telephones 7734 FB10 FB20 SK1 Soft Keys SK2 SK3 SK4 FB09 FB19 FB08 FB18 FB07 FB17 FB06 FB16 FB05 FB15 FB04 FB14 FB03 FB13 FB02 FB12 FB01 FB11 FB01 FB02 FB03 FB04 FB05 FB06 FB07 FB08 FB09 FB10 FB buttons for 20 button phones IPT1020 SD and IPT2020 SD FB buttons for 10 button phones IPT2010 ...

Page 19: ...CIX Telephones Administrator Manual 06 06 9 5442UK FB01 FB02 FB03 FB04 FB05 FB06 FB07 FB08 FB09 FB10 FB11 FB12 FB13 FB14 FB buttons for 14 button phones DKT3X14 SDL Msg Spdial Redial Mic Spkr Cnf Trn Hold Vol Z Q Feature Scroll Mode Page ...

Page 20: ... Programming Mode the flexible buttons are numbered as Feature Buttons as shown at the beginning of this chapter To place your telephone in Programming Mode Press 3 6 9 Hold simultaneously The LCD displays DKT PROGRAM MODE and SELECT Your phone will not ring if it receives a call while in Programming Mode To exit from Programming Mode Go Off and On hook or wait for 30 seconds for Programming Mode ...

Page 21: ...eep 4 Press Hold to set the option 5 You must also go off hook then on hook to exit the program mode Speakerphone Microphone Sensitivity Adjustment When you are using the speakerphone high ambient noise levels may cause the party you are talking with to be to cut off frequently If this happens follow these steps to lower the sensitivity of the microphone on a DKT3000 3200 3500 series telephone The...

Page 22: ...ess Feature Button 4 FB4 to toggle On Off FB4 LED On Call Waiting tone FB4 LED On No Call Waiting tone 4 Press Hold to set the option 5 Go off hook then on hook to exit the program mode Reset and Adjust the LCD Contrast To adjust LCD Contrast for the LCD Telephones 1 Press 3 6 9 Hold simultaneously 2 Press and hold down the Mic button and press and release Vol or Vol repeatedly Each time you press...

Page 23: ...mode Test the Display on Large LCD Telephones DKT3014 SDL only 1 Press 3 6 9 Hold simultaneously 2 Press SK2 3 Press 1 LCD screen is blank 4 Press 2 Each segment shows three vertical lines in all eight rows 5 Press 3 Each segment contains five short horizontal lines in all eight rows 6 Press 4 Each segment contains a pattern of small dots in all eight rows 7 Press 5 All of the available characters...

Page 24: ...ld simultaneously 2 Press 0 7 3 Press Msg to toggle On Off Msg LED On Flex button works as Feature Button FB3 Msg LED Off Flex button works as a Redial button 4 Press Hold to set the option 5 Go off hook then on hook to exit the program mode Notes If you program the Flex button to work as Flexible Button 3 you can press to redial If the Flex button is changed to function as FB3 FB3 must be assigne...

Page 25: ...below 1 Press 3 6 9 Hold simultaneously 2 Press 3 Press FB1 FB2 FB3 see table below and check these LEDs 4 Press Hold In Off hook it returns to normal mode Important On the IPTs the soft keys do not have names such as Page Mode Scroll and Feature In the manual the soft keys are referenced as SK1 SK2 SK3 and SK4 from Left to Right On the IPT2010 SD use the soft key SK3 Scroll to switch between FB1 ...

Page 26: ...01 to initialise the telephone s function settings LED On initialise LED Off don t initialise See IP Telephone Function Settings on page 19 for details 4 Press FB02 to initialise LCD contrast setting LED On initialise LED OFF don t initialise 5 Press FB03 to initialise the telephone s IP network connection settings LED On initialise LED Off don t initialize See IPT Setup Instructions below for det...

Page 27: ...bove is set for manual setting 7 Press FB5 Enter a Station ID for the IPT and press Hold This is usually your telephone s primary number PDN 8 Press FB6 to enter the CIX Strata Net node number of the CIX node that contains the LIPU to which this IPT interfaces then press Hold This FB setting is for CIX networked systems only 9 Press FB11 for LIPU address mode Press one of the following 1 manual se...

Page 28: ... out continuously 3 IPT searches for BIPU LIPU Retries every 10 seconds Possible errors BIPU is not found time out BIPU is not found Station ID automatic setting BIPU is not found StationID manual setting Multicast address is not registered BIPU IP address setting mode is automatic setting by multicast BIPU IP address is not registered BIPU IP address setting mode is manual setting INITIALISING PL...

Page 29: ...o off hook and hang up 4 Registering to BIPU When registering fails IPT retries by starting at Step 2 again Error message Exxx is error number 5 Registering completion normal action LCD data is indicated from the system Example Table 3 IP Telephone Function Settings FB LED ON LED OFF FB1 Buttons beep Buttons do not beep FB3 Speakerphone Microphone sensitivity is lower Speakerphone Microphone sensi...

Page 30: ...D Off without 5 Press Hold to set the above data 6 Go off hook and hang up Viewing IP Telephone Terminal Information 1 Press 3 6 9 Hold simultaneously 2 Press 1 then press Hold 3 Press FB1 to view IPT firmware version application and boot versions read only 4 Press FB2 to view IPT MAC address read only 5 Go off hook and hang up Table 4 Volume Level Transmitted from Headset Microphone LEDS Transmit...

Page 31: ...relates to an item on the Configurations screen Press the soft key that corresponds to the item The details pertaining to that item display Note The following table explains each of the items displayed on the Configurations screen ITEM INFORMATION DISPLAY Term Info Displays the Software Version the MAC address and the Regional Code You can press the EXIT soft key to go back to the Configurations s...

Page 32: ...third line Ping result is confirmed only on this screen Network Displays or sets the DHCP IP Address Subnet the default gateway station information and LIPU Address Advance Displays the Primary Name Server the Secondary Name Server GRQ Port RRQ Port and AP Address Sound Displays settings for Keybeep Roam Noise Handset BOV and Carbon Headset Others Key Repeat Net Diag Factory Initialise Reset ITEM ...

Page 33: ...e Note Pressing the SET soft key can cause the screen to move to the Input Error Screen if an error occurred when entering the IP address shown right 4 Press the OK soft key on the Error Screen to go to the Address Setting Screen Note In five seconds after displaying the Input Error Screen the screen automatically moves to the Address Setting Screen The address that has resulted in an input error ...

Page 34: ...p Back Test Screen The result is displayed in the third line of the Loop Back Test Screen as Last result n 10 successful operations 10 During Ping execution the progress is displayed by showing Executing n 10 number of successful operations number of trial operations in the third line on the Pinging Screen Pressing the Ping Stop or EXIT key on the Pinging Screen will stop Pinging and cause the scr...

Page 35: ... the SET soft key to rewrite the NV RAM data if any setting of a minor item is changed The screen will move to the Resetting Selection Screen The Resetting Selection Screen will be described in detail later Press the SET soft key to go to the Configurations Screen without rewriting the NV RAM data if no setting change of a minor item is made Press the CANCEL soft key to cancel all the intended set...

Page 36: ...ey to accept the change or press the CANCEL soft key to cancel the change Notes The Network Setting Screen displays when you press SET or CANCEL DHCP is underlined in the display if you changed the setting If the DHCP setting is changed from ON to OFF then the IP Addr setting on the Network Setting screen will be initialised to the initial value The IPT2008 SDL gets its IP address Subnet mask Defa...

Page 37: ...nd go back to the Network Setting Screen On the Network Setting Screen the item you changed will be underlined in the display in this case the IP Address 3 Pressing the SET soft key can give you an Error Screen if you incorrectly entered the address 4 Press the OK soft key on the Error Screen to correct the entry Five seconds after the Error Screen displays the screen automatically goes back to th...

Page 38: ... the steps to change settings on page 27 Default Gateway Address 1 Select Configuration Network Dflt GW The Default GW Address screen displays shown right The current default Gateway Address displays on the one line text field 2 Follow the steps to change settings on page 27 Subnet Mask 255 255 255 0 Current New Backspace Vol Down SET CANCEL CONFIG PHONE WEB Default GW Address 0 0 0 0 Current New ...

Page 39: ... Error Screen if you incorrectly entered the Station ID Press the OK soft key on the Error Screen to correct the entry Five seconds after the Error Screen displays the screen automatically goes back to the appropriate setting screen in this case the IP Address and the address that resulted in an error will be displayed Node Number 1 Select Configuration Network Setting Screen 2 Node The current No...

Page 40: ...ue set is underlined in the display 3 Press the SET soft key to accept the change or press the CANCEL soft key to cancel the change and go to the Network Setting screen CIX System IPU Address Screen 1 Select Configuration Network Setting Screen 2 IPU Address The IPU Address displays shown right 2 Follow the steps to change settings on page 27 IPU Mode Manual Broadcast SET CANCEL CONFIG PHONE WEB I...

Page 41: ...o that item Press the SET soft key to rewrite the NV RAM data if any setting of a minor item is changed The screen will move to the Resetting Selection Screen The Resetting Selection Screen will be described in detail later Press the SET soft key to go to the Configurations Screen without rewriting the NV RAM data if no setting change of a minor item is made Press the CANCEL soft key to cancel all...

Page 42: ...ress screen displays shown right 2 Follow the steps to change settings on page 27 GRQ Port Number 1 Select Configuration Advanced GRQ Port The current GRQ Port Number displays shown right 2 Enter the New number 3 Press the SET soft key to accept the change or press the CANCEL soft key to cancel the change and go to the Network Setting screen Note For other notes refer to Station ID on page 29 Prim...

Page 43: ...een Note For other notes refer to Station ID on page 29 Application Server Address 1 Select Configuration Advanced AP Addr The current Application Server Addr screen displays shown right Note The Application Server Address can be an IP Address or a URL alphanumeric See Dial Pad Alphanumeric Characters on page 34 to enter the URL 2 Follow the steps to change settings on page 27 RRQ Port Number 0 Cu...

Page 44: ...pad button 1 2 3 4 5 6 7 8 9 1 space 2 a b c A B C goto a 3 d e f D E F goto d 4 g h i G H I goto g 5 j k l J K L goto j 6 m n o M N O goto m 7 p q r s P Q R S goto p 8 t u v T U V goto t 9 w x y z W X Y Z goto w 0 1st _ 0 2nd 0 3rd 0 4th l goto Press Vol button to back space Press 0 for all punctuation marks Press to toggle between Alpha and Numeric modes Press to enter a period ...

Page 45: ...right 2 To change settings follow the steps on page 27 External Administration Terminal IP Address Lower Bound Setting This screen can be used to set an External Administration Terminal IP Address Upper Bound External accessing is not enabled if the Upper and Lower bound IP addresses are initial values 0 0 0 0 External accessing is enabled if the External Administration Terminal IP address is with...

Page 46: ...al Administration Password Setting Select Configuration Advanced Screen 2 PASSWORD The Password screen displays shown right To change or add a new password Note The Password can be alphanumeric see Dial Pad Alphanumeric Characters on page 34 to enter the Password 1 Press the Current soft key left then enter the Current Password 2 Press the New soft key left then enter the New Password 3 To confirm...

Page 47: ... rewrite the NV RAM data if any setting of a minor item is changed The screen will move to the Resetting Selection Screen The Resetting Selection Screen will be described in detail later Press the SET soft key to go to the Configurations Screen without rewriting the NV RAM data if no setting change of a minor item is made Press the CANCEL soft key to cancel all the intended setting changes in the ...

Page 48: ...he SET soft key to accept the change or press the CANCEL soft key to cancel the change The setting is underlined in the Sound screen display Headset Tx Control Setting Screen 1 Select Configuration Sound screen 2 Headset Tx Ctl The Headset Tx Control screen displays 2 Press the Low or Normal soft keys to change the set value 3 Press the SET soft key to accept the change or press the CANCEL soft ke...

Page 49: ...ctly entered the Station ID Press the OK soft key on the Error Screen to correct the entry Five seconds after the Error Screen displays the screen automatically goes back to the Headset Tx Volume screen and the number that resulted in an error will be displayed Handset Rx Output Setting and Comfort Noise Setting Important The following steps apply to the above two items 1 Select Configuration Soun...

Page 50: ...ed Press the CANCEL soft key to cancel all the intended setting changes in the minor items and to go to the Configurations Screen without rewriting the NV RAM data Key Repeat OFF ON 1 Select Configuration Key Repeat OFF ON The OFF ON Setting screen displays 2 Press the ON or OFF soft keys to change the set value 3 Press the SET soft key to accept the change or press the CANCEL soft key to cancel t...

Page 51: ... Repeat Delay Timer 1 short to 5 long For Repeat Rate Timer 1 fast to 5 slow 2 Press the SET soft key to accept the change or press the CANCEL soft key to cancel the change and go to the Network Setting screen Notes Pressing the SET soft key can give you an Error Screen if you incorrectly entered the Station ID Press the OK soft key on the Error Screen to correct the entry Five seconds after the E...

Page 52: ...figuration screen after rewriting the NV RAM data Press the CANCEL soft key to cancel all the intended setting changes in the minor items and to go to the Configurations Screen without rewriting the NV RAM data Language Mode Setting 1 Select Configuration Others Language The Language Mode screen displays 2 Press the English US CA English UK French or Spanish soft keys to change the set value 3 Pre...

Page 53: ...this screen 1 Enter the New Repeat Delay Timer to change the setting Note Use the dial pad 1 3 and Vol to backspace For Input Timer Value 1 fast to 3 slow 2 Press the SET soft key to accept the change or press the CANCEL soft key to cancel the change and go to the Other Setting screen Notes Pressing the SET soft key can give you an Error Screen if you incorrectly entered the Station ID Press the O...

Page 54: ... will not cancel the selection Pressing the EXEC soft key while Network is displayed underlined will initialise the selected item and will rewrite the NV RAM data and cause the screen to move to the Resetting Selection Screen The Resetting Selection Screen will be described later Pressing the EXEC soft key any item except Network is displayed underlined will rewrite the NV RAM data and go to the C...

Page 55: ... address setting Manual broadcast broadcast 8 Libra Server IPU IP address setting during manual setting 0 0 0 0 Network Setting Advanced 1 IP address setting for DNS Server Primary Name Server 0 0 0 0 2 IP address setting for DNS Server Secondary Name Server 0 0 0 0 3 GRQ port number 1024 65535 1718 4 RRQ port number 1024 65535 1719 5 IP address setting for application server 0 0 0 0 6 External ad...

Page 56: ... Rx output ON OFF OFF 9 Comfort noise ON OFF ON Key Repeat Setting 1 Key repeat OFF ON ON 2 Repeat delay timer 1 Short ñ 5 Long 1 3 Repeat rate timer 1 Fast ñ 5 Slow 1 Other Setting 1 Language mode English US CA English UK French Spanish English US CA 2 Input timer mode ON OFF OFF 3 Input timer value 1 Fast ñ 3 Slow 1 Fast ñ 3 Slow Factory Setting 1 ADM DEBUG mode DEBUG ADM ADM 2 Display Key Test ...

Page 57: ...Reset will flicker black and white to prompt you to reset Reset does not flicker if there were no setting changes in subsidiary items Factory Select Configuration Factory The Factory Setting screen displays The general operation on the Key Repeat screens is as follows To view details of an item displayed on the screens above press the soft key that corresponds to that item Press the SET soft key t...

Page 58: ...ess the soft key next SK01 SK14 The SKxx displays in the center of the screen Key Test mode shown right 3 Select the LCD on the Display Key Test Mode Screen then the screen to move to the Display Test Mode Screen See Figure on page 49 Notes Pressing the SK01 SK14 soft keys seven test patterns appear When the SK01 SK14 soft key is pressed seven times the screen returns to the Display Key Test Mode ...

Page 59: ... Mode Screen CONFIG PHONE TEST WEB Select the LCD and press the enter key Select the LCD and press the enter key Factory Setting ADM DEBUG Mode ADM Display Key Test Display Mode IPT2008 SET CANCEL Display Key Test Mode Screen Factory Setting Screen CONFIG PHONE TEST WEB Press the EXIT Key When the SK key SK01 to SK14 key is pressed 7 times after move to the Key Test Mode Screen SK01 LCD EXIT SK02 ...

Page 60: ...ory Display Mode The Display Mode screen displays 2 Press the IPT2008 or DKT3014 soft keys to change the set value Press the SET soft key to accept the change or press the CANCEL soft key to cancel the change The setting is underlined in the Factory Setting screen display Display Mode IPT2008 DKT3014 SET CANCEL CONFIG PHONE WEB ...

Page 61: ...opean Norm IMPORTANT SAFETY NOTES 1 1 Both systems must have an earth connection and must be hardwired to a main distribution point The main cabinet must be earthed 1 2 Table A 1 below identifies and classifies the ports available on the system Table A 1 Type of Circuit EN60950 Classification Port Location Port Description SELV Power SupplyBPSU672F APSU112F CHSUB192F For connection of external 24 ...

Page 62: ... TNV2 PACU2F PACU3F 4 Cct AC15 Private Circuit I F TBR17 For connection to PTO Private Circuit services TNV2 PEMU2F REMU 4 Cct DC5 Private Circuit I F TBR 17 For connection to PTO Private Circuit services SELV BIOU1A Contains various ports for connection of audio paging amplifiers dry relay contacts to control external equipment SELV BVPU1A BIPUM2A BIPQ1A LIPU X1A Voice Over IP interface cards Hou...

Page 63: ...ecting device as specified in the standard EN60950 the switch on the fused spur outlet shall be considered the AC power disconnection device This spur must be installed in accordance with 16th edition of the IEE wiring regulations aka BS7671 1992 Or the latest edition of this standard The Strata CIX Office system must be hardwired into a switched fused spur which should comply with the requirement...

Page 64: ...ecific standards EN55022 1998 9 EN IEC61000 3 2 1995 EN IEC61000 3 3 1995 Emissions EN52024 1998 EN61000 4 2 1995 A1 1998 EN61000 4 3 1997 A1 1998 EN61000 4 4 1995 A1 2001 EN61000 4 5 1995 A1 2001 EN61000 4 6 1995 A1 2001 Immunity The notes listed below form part of the products compliance with the aforementioned European Norm To ensure EU compliance the system must installed in accordance with th...

Page 65: ...ns Expansion Cabinet Dimensions Height 370mm Width 303mm Depth 259mm Weight 8 8kg fully equipped Height 370mm Width 230mm Depth 259mm Weight 6 9kg fully equipped Base Cabinet Dimensions Expansion Cabinet Dimensions Height 296mm Width 672mm Depth 270mm Weight 14 1kg fully equipped Height 254mm Width 672mm Depth 270mm Weight 13 2kg fully equipped Base Cabinet Dimensions Expansion Cabinet Dimensions ...

Page 66: ... below lists the intended purposes of the relevant system network interfaces Table A 2 Interface Type Network Service The system must be installed in accordance with BS6701 parts 1 and 2 the latest issue shall apply Toshiba Information Systems claim approval to OFTEL general variation NS V 1235 P 100020 The information contained in this paragraph supports Toshiba s claim The following features req...

Page 67: ...llers access to an outgoing exchange line There is an engineering programming parameter which can disable these features In addition the DISA feature can be password protected USERS SHOULD BE AWARE THAT THESE FEATURES CAN BE USED FOR FRAUDULENT PURPOSES Please consult your supplier to ensure any necessary security measures are enabled ...

Page 68: ...1300Hz 7 1000 800Hz 8 1000 800Hz 9 660 500 10 2000Hz 11 2000Hz 10Hz Intrpt 12 860 1180Hz T1 1300 1780Hz T2 1s On 3s Off OR 1sOn 1s Off 1s On 3s Off OR 1sOn 1s Off 1s On 3s Off OR 1sOn 1s Off T1 0 5s ON T2 0 5s On 3s Off OR T1 0 5s ON T2 0 5s On 3s Off 1s On 3s Off 1s On 1 S Off 0 6s On 1000Hz 0 6s On 800Hz 0 6s On 1000Hz 0 6s 800Hz 0 7s On 660Hz 0 7s On 500Hz 1s On 3s Off 1s On 1 S Off T1 0 5s ON ...

Page 69: ...0Hz 2 400 T1 350 440Hz T2 3 350 440Hz 4 400 450Hz 5 400Hz 6 400Hz 7 400Hz 8 440Hz 9 350 440Hz 10 1209Hz T1 500Hz T2 11 350 440Hz 12 2000Hz 13 2000Hz 14 350 440Hz Continuous 4 bursts of 0 125s T2 3s On 5 bursts of 0 1s 3s On 0 4s On 0 2s Off 0 4s On 2s Off 0 375s On 0 375s Off Repeated 0 375s On 0 375s Off Repeated 0 375s On 0 375s Off Repeated 1s On 3 bursts of 0 1s T1 3 bursts of 0 25s T2 0 25s t...

Page 70: ...ts the measured loudness rating of the Toshiba proprietary terminals SLR and RLR 0km PSTN All values are dB Table A 5 System Port Type PDKU2A BDKU BDKS ITS A to fm to fm to fm to fm to fm to fm PCOU2F RCOU 3 7 3 7 1 8 1 9 1 8 1 9 3 1 3 2 0 7 1 5 RPTU1F 2F 1 9 1 8 0 0 0 0 RBSU2A 1 9 1 8 0 0 0 0 PEMU2F REMU 3 1 3 2 1 3 1 3 1 3 1 3 2 6 2 6 2 0 2 0 PACU2F PACU3F 0 7 1 5 3 4 2 5 3 4 2 5 2 0 2 0 6 0 6 0...

Page 71: ...ide 12 buttons extension iv C camp on ring tone 12 D deactivation 14 digital telephone upgrade busy override camp on ring tone over handset headset 12 microphone speaker sensitivity adjustment 11 E extension number iv F feature button activation 14 I IPT1020 SD 21 M microphone speaker sensitivity adjustment 11 R redial 14 S speakerphone 11 T transmission levels 15 ...

Page 72: ...Index T T 62 Strata CIX Telephones Administrator Manual 6 06 ...