Worksheet 2 – System Power Factor Check
2-20
Strata DK I&M 6/00
PCB and Power Factor Worksheets
See examples on previous pages.
Note
If power factors exceed the maximum (+5VDC= 14, -24VDC = 39), the system size must
be reduced to stay within PF limits
Table 2-24
DK40i Telephone/Device Power Factor Worksheet (Base and Expansion Telephones)
Telephone Devices
Quantity Installed
X
-24VDC PF
=
-24VDC PF
Total
2000-series Digital Telephone (any series)
X
1.0
=
Cordless Digital Telephone (DKT2004-CT)
X
1.0
=
2000-series Electronic Telephone
X
2.0
=
3000-series Electronic Telephone
X
2.5
=
6000-series Electronic Telephone
X
2.0
=
6005-series Electronic Telephone
X
2.0
=
6500-series Electronic Telephone
X
1.0
=
DDCB/HDCB (w. MDFB)
X
1.2
=
DDSS/HDSS Console
X
0.8
=
Add-on Module
X
0.4
=
RPCI-DI
X
0.5
=
PDIU-DI2 and PDIU-DS
X
0.8
=
Standard Telephone (-48VDC)
X
1.0
=
Standard Telephone (-24VDC)
X
0.5
=
Power Failure Unit (DPFT)
X
3.0
=
HHEU
X
0.1
=
Stratagy DK
X
1.0
=
Total -24VDC PF of all Telephone Devices
=
Table 2-25
Power Factor Worksheet
Base PCBs
PCB Installed
+5 Volt PF
-24 Volt PF
Yes
No
K5RCU2
K5RCU
K4RCU3
TSIU
TCOU
TBSU
TBUU
KSTU2
TDDU
TCIU
Expansion Unit PCBs
PCB Name
Slot 15
Slot 16
Slot 17
Slot 18
-24VDC PF of telephones/devices from
Total DK40i PF =
Summary of Contents for Strata AirLink DK40i
Page 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Page 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Page 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Page 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Page 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Page 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Page 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Page 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Page 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...